Skip Navigation



NDT Advance Access published online on January 25, 2007

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfl750
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
22/4/1205    most recent
gfl750v3
gfl750v2
gfl750v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Hermans, M. M. H.
Right arrow Articles by Leunissen, K. M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hermans, M. M. H.
Right arrow Articles by Leunissen, K. M. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2007]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Spatial inhomogeneity of common carotid artery intima media is increased in dialysis patients

Marc M. H. Hermans1, Jeroen P. Kooman1, Vincent Brandenburg2, Markus Ketteler2, Jan G. M. C. Damoiseaux3, Jan W. Cohen Tervaert3, Isabel Ferreira4,9, Pieter L. Rensma5, Ulrich Gladziwa6, Abraham A. Kroon7, Arnold P. G. Hoeks8, Coen D. A. Stehouwer9 and Karel M. L. Leunissen1

1Department of Internal Medicine and Nephrology, Academic Hospital Maastricht, Maastricht, Netherlands, 2Department of Nephrology and Clinical Immunology, University Hospital RWTH, Aachen, Germany, 3Department of Clinical and Experimental and Immunology, Academic Hospital Maastricht, Maastricht, 4Department of Clinical Epidemiology and Medical Technology Assessment, Academic Hospital Maastricht, Maastricht, Netherlands, 5Department of Internal Medicine and Nephrology, Elisabeth Hospital Tilburg, Netherlands, 6University of Witten-Herdecke,Witten, Germany, 7Department of Internal Medicine and Vascular Medicine, Academic Hospital Maastricht, Maastricht, 8Department of Biophysics, Maastricht University and 9Department of Internal Medicine, Academic Hospital Maastricht, Maastricht, Netherlands

Correspondence and offprint requests to: Marc M. H. Hermans, MD, Department of internal medicine and nephrology, Academic Hospital Maastricht, PO box 5800, 6202 AZ Maastricht, The Netherlands. Email: mherm{at}sint.azm.nl



  Abstract

Background. Structural abnormalities of the common carotid artery (CCA), as assessed by ultrasound techniques, are related to cardiovascular outcome in dialysis patients. An increased intima media thickness (IMT) of the CCA may both represent a reaction to a haemodynamic burden as well as atherosclerosis. With a new ultrasound technique CCA-IMT and IMT-inhomogeneity, a novel parameter of spatial variance of the IMT, were measured and related to traditional and non-traditional risk factors.

Methods. In a cross-sectional study, we included 134 dialysis patients, aged 61 ± 13 years (103 on haemodialysis, 31 on peritoneal dialysis) and 41 controls, aged 60 ± 8 years. Age, sex, pulse pressure, diabetes, prevalent cardiovascular disease (CVD) and height were included in the basic multiregression analysis. Ultrasound examination of the CCA was performed. We also measured serum fetuin-A, high-sensitivity C-reactive protein (hsCRP), antibodies to oxidized low density lipoproteins (anti-oxLDL antibodies), calcium, phosphate, albumin and parathyroid hormone.

Results. Compared with controls, dialysis patients had a greater CCA-IMT (670 µm vs 590 ± 10 µm; P = 0.002) and a greater CCA-IMT inhomogeneity (11.0 vs 8.1%; P = 0.013). Dialysis patients with CVD had a greater CCA-IMT (734 µm vs 631µm; P = 0.001) and IMT-inhomogeneity (13.2 vs 9.7; P = 0.008) compared with patients without CVD. IMT-inhomogeneity strongly correlated with IMT (R = 0.65, P < 0.0001). In multiregression analysis, serum fetuin-A and anti-oxLDL antibodies correlated with IMT-inhomogeneity but not with IMT. HsCRP neither correlated with IMT-inhomogeneity nor with IMT.

Conclusion. The present study shows that CCA-IMT and IMT-inhomogeneity were increased in dialysis patients compared with controls. Although CCA-IMT and IMT-inhomogeneity are related, the different associations between both measurements and non-traditional risk factors show that they are distinct entities.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
G. Schlieper, M. Hristov, V. Brandenburg, T. Kruger, R. Westenfeld, A. H. Mahnken, E. Yagmur, G. Boecker, N. Heussen, U. Gladziwa, et al.
Predictors of low circulating endothelial progenitor cell numbers in haemodialysis patients
Nephrol. Dial. Transplant., August 1, 2008; 23(8): 2611 - 2618.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.