Skip Navigation



NDT Advance Access published online on September 23, 2006

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfl550
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
22/1/96    most recent
gfl550v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Giapros, V.
Right arrow Articles by Andronikou, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giapros, V.
Right arrow Articles by Andronikou, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2006]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received May 17, 2006
Accepted August 16, 2006


Original Article

The effect of intrauterine growth retardation on renal function in the first 2 months of life

Vasileios Giapros 1 *, Photeini Papadimitriou 1, Anna Challa 2, and Styliani Andronikou 1

1 Neonatal Intensive Care Unit, Child Health Department, University of Ioannina, Greece
2 Research Laboratory of the Child Health Department, University of Ioannina, Greece

* To whom correspondence should be addressed.
Vasileios Giapros, E-mail: vgiapros{at}cc.uoi.gr



  Abstract

Background. Children born with growth retardation (GR) have a smaller nephron number and are at increased risk for the development of renal disease and hypertension in adult life. Data on the immediate post-natal development of renal function in neonates born with GR are limited and data on the effects of aminoglycosides (AGs) on renal function in these infants are lacking.

Methods. This was a prospective study of 81 preterm neonates with a mean gestational age of 32.5 weeks, 40 born with GR (small for gestational age, SGA) and 41 without GR (appropriate for gestational age, AGA). The infants were classified into 4 groups. Groups A (n = 21) and B (n = 20) consisted of AGA and SGA neonates, respectively, who received AGs, and groups C (n = 20) and D (n = 20) of AGA and SGA neonates, respectively, who did not receive AG treatment. Indices of renal function were: serum creatinine (SeCr), the fractional excretion of sodium (FENa), potassium (FEK), phosphorus (FEP), magnesium and uric acid (FEUA), the urinary calcium/creatinine ratio and the transtubular potassium gradient (TTKG).

Results. No differences were observed in the parameters examined between SGA and AGA neonates who did not receive AGs. Conversely, SGA infants who received AGs after birth (group B) exhibited higher values of SeCr 2 months later. Specifically, their mean ± SD value of SeCr (µmol/l) was 42 ± 05 compared with 33 ± 08 in group D, 35 ± 04 in group A and 33 ± 04 in group C (P < 0.01). These infants also had significantly higher values of TTKG than SGA infants without AG treatment (22 ± 9 vs 13 ± 3 in group D) and FEUA (60 ± 23 vs 35 ± 14 in group D). Their FENa and FEP were also inappropriately high despite having lower serum levels of Na and P.

Conclusion. Preterm SGA infants who had no need of AG treatment after birth have similar renal functional maturation than AGA preterm infants at 2 months of life, but preterm SGA infants who received AGs had indications of impaired glomerular and tubular function at this age.

Keywords: aminoglycosides; FENa; renal function; small for gestational age; transtubular potassium gradient (TTKG); tubular function.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.