Skip Navigation


NDT Advance Access first published online on December 19, 2005
This version published online on December 21, 2005

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfi340
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
21/3/802    most recent
gfi340v3
gfi340v2
gfi340v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Planken, R. N.
Right arrow Articles by Tordoir, J. H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Planken, R. N.
Right arrow Articles by Tordoir, J. H. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2005]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received October 3, 2005
Accepted November 23, 2005


Technical Note

Diameter measurements of the forearm cephalic vein prior to vascular access creation in end-stage renal disease patients: graduated pressure cuff versus tourniquet vessel dilatation

R. Nils Planken 1 *, Xavier H. A. Keuter 2, Arnold P. G. Hoeks 3, Jeroen P. Kooman 4, Frank M. van der van der Sande 4, Alfons G. H. Kessels 5, Tim Leiner 6, and Jan H. M. Tordoir 2

1 Departments of Vascular Surgery, Maastricht University Hospital, Maastricht, The Netherlands; Departments of Radiology, Maastricht University Hospital, Maastricht, The Netherlands; Cardiovascular Research Institute Maastricht and Maastricht University Hospital, Maastricht, The Netherlands
2 Departments of Vascular Surgery, Maastricht University Hospital, Maastricht, The Netherlands; Cardiovascular Research Institute Maastricht and Maastricht University Hospital, Maastricht, The Netherlands
3 Departments of Biophysics, Maastricht University Hospital, Maastricht, The Netherlands; Cardiovascular Research Institute Maastricht and Maastricht University Hospital, Maastricht, The Netherlands
4 Departments of Nephrology, Maastricht University Hospital, Maastricht, The Netherlands; Cardiovascular Research Institute Maastricht and Maastricht University Hospital, Maastricht, The Netherlands
5 Departments of Clinical Epidemiology Medical Technology Assessment, Maastricht University Hospital, Maastricht, The Netherlands
6 Departments of Radiology, Maastricht University Hospital, Maastricht, The Netherlands; Cardiovascular Research Institute Maastricht and Maastricht University Hospital, Maastricht, The Netherlands

* To whom correspondence should be addressed.
R. Nils Planken, E-mail: N.Planken{at}surgery.azm.nl



  Abstract

Background. Preoperative assessment of forearm superficial venous diameter may predict early failure of newly created arteriovenous fistulas for haemodialysis access. However, early failure and non-maturation rates remain high (up to 30%) and reported cut-off diameters are inconsistent. We hypothesize that this inconsistency is due to differences in the methods used to achieve venous dilatation prior to diameter measurements and daily variation in superficial venous diameter. We furthermore hypothesize that the use of a cuff will lead to a better inter-observer agreement since the applied pressure can be precisely determined. The purpose of this study was to determine inter-observer agreement of superficial venous diameter measurement under venous congestion by using either a graduated pressure cuff or tourniquet and furthermore, to determine daily variations in superficial venous diameter.

Methods. Diameter measurements were performed by two observers on days 1 and 3, in 21 end-stage renal disease patients using either a cuff (60 mmHg) or tourniquet. Measurements were carried out in random order and observers were blinded for each other's results. Inter-observer agreement was expressed as interclass correlation coefficients. Variance components analysis was used to determine possible causes of disagreement.

Results. Using a cuff, mean venous diameter was 1.8 mm (range, 0.7-3.3 mm). When a tourniquet was used, the mean diameter was 1.8 mm (range, 0.6-3.2 mm). Interclass correlation coefficients between observers were 0.76 and 0.74 for the use of a cuff and tourniquet, respectively. Diameter measurements were revealed to be observer independent. Variations in venous diameter were determined by the patient and the interaction of patient and day. Repeated assessment of venous diameter on different days revealed a variation coefficient of 26.4% when using a cuff, and 26.5% when using a tourniquet.

Conclusions. Venous diameter assessment is observer and congestion method independent. Daily variations in forearm superficial venous diameters should be taken into account when defining and using cut-off diameters prior to vascular access surgery.

Keywords: arteriovenous fistula; haemodialysis; ultrasonography; vascular access; vascular surgery; vein.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
M. Ferring, J. Henderson, A. Wilmink, and S. Smith
Vascular ultrasound for the pre-operative evaluation prior to arteriovenous fistula formation for haemodialysis: review of the evidence
Nephrol. Dial. Transplant., June 1, 2008; 23(6): 1809 - 1815.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.