Skip Navigation



NDT Advance Access published online on March 15, 2005

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfh759
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
20/6/1164    most recent
gfh759v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Arenas, M. D.
Right arrow Articles by Angoso, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arenas, M. D.
Right arrow Articles by Angoso, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2005]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org
Received July 2, 2004
Accepted December 17, 2004


Original Articles

A multicentric survey of the practice of hand hygiene in haemodialysis units: factors affecting compliance

M. Dolores Arenas 1*, José Sánchez-Payá 2, Guillermina Barril 3, Juan García-Valdecasas 4, Jose Luis Gorriz 5, Antonio Soriano 6, Andres Antolin 7, José Lacueva 8, Sergio García 9, Ana Sirvent 10, Mario Espinosa 11, and Manuel Angoso 12

1 Hospital Perpetuo Socorro, Alicante, Spain; Haemodialysis Unit, Elda, Spain; Haemodialysis Unit, Elche, Spain
2 Unidad de Control de Infecciones y Epidemiología de Hospital de Alicante, Spain
3 Hospital de la Princesa, Madrid, Spain
4 Hospital Dr Peset, Spain
5 Hospital Clínico, Granada, Spain
6 Haemodialysis Unit, Elda, Spain
7 Cediat-Aldaia, Spain
8 Cediat-Turia, Spain
9 Hospital de Poniente, Almeria, Spain
10 Haemodialysis Unit, Elche, Spain
11 Hospital Reina Sofía, Córdoba, Spain
12 Clinica Virgen del Consuelo Valencia, Spain

* To whom correspondence should be addressed.
M. Dolores Arenas, E-mail: arenasd{at}perpetuosocorro.nehos.com



  Abstract

Background. This study intended to investigate the degree of compliance with hand hygiene and use of gloves by health workers in haemodialysis (HD) units, and the factors that influenced adherence to hand hygiene protocols.

Methods. During the month of November 2003, one person observed the health care staff in each of nine different dialysis units, during 495 randomly distributed 30 min observation periods that covered all steps of a haemodialysis session (connection, dialysis and disconnection). The observers noted the number of potential opportunities to implement standard precautions and the number of occasions on which the precautions were actually taken. Adherence to standard precautions was evaluated, analysing the influence of the following variables: the patient-to-nurse ratio, the number of HD shifts scheduled per day, acute HD units vs chronic, whether or not infectious patients were isolated and in-house vs contract cleaning personnel.

Results. There were a total of 977 opportunities to wear gloves for, and to wash the hands following, a patient-oriented activity, and 1902 opportunities to wash hands before such an activity. Gloves were actually used on 92.9% of these occasions. Hands were washed only 35.6% of the time after patient contact, and only 13.8% of the time before patient contact. Poor adherence to hand washing was associated with the number of shifts per HD unit per day and with higher patient-to-nurse ratios. In the acute HD units, there was greater adherence to standard precautions than in the chronic units, although there too it was substandard. The personnel's knowledge of patients’ infectious status did not modify their adherence to hand hygiene practices. A higher patient-to-nurse ratio independently influenced hand washing both before and after patient contact.

Conclusions. The overall adherence of health care workers to recommended hand washing practices is low. Whether or not programmes promoting higher hand hygiene standards and the potential use of alcohol-based hand cleansers will improve hand hygiene practices in HD units requires further investigation.

Keywords: haemodialysis; hand hygiene; hepatitis C prevention; standard universal precautions.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.