Background. Vascular access is judged on its ability to provide good dialysis adequacy, its durability and complication rates. Formation of a functional arteriovenous fistula is desirable but difficult to achieve in a significant proportion of patients. We report the large-scale use of Tesio-Caths, a twin-line single-lumen central venous catheter, to maximize dialysis adequacy where formation of an arteriovenous fistula was not possible. Methods. All patients who had Tesio-Caths inserted between 1 January 1999 and 1 October 2002 were studied. Results. Six hundred and twenty-three Tesio-Caths were inserted from 1 January 1999 to 1 October 2002 in 435 patients, generating 7464 patient months of follow-up. Five hundred and ninety-four out of 623 (95.3%) Tesio-Caths were immediately functional. Mean dialysis adequacy measured by single-pool Kt/V was 1.5±0.3 for all Tesio-Caths for the entire period of study, with 68% of Tesio-Caths delivering a Kt/V >1.4. Cumulative functional Tesio-Cath survival to final failure was 77.8 and 44% at 1 and 3 years, respectively. Cumulative patient survival was 84.7, 71.4 and 63% at 1, 2 and 3 years, respectively. Access-related infection accounted for 0.28 admissions/1000 catheter days, and the death rate from access-related sepsis was 9.6 deaths/1000 patient years at risk. The admission rate for access dysfunction was 0.33/1000 patient years at risk. Conclusion. Tesio-Caths provide good dialysis adequacy for patients in whom an arteriovenous fistula cannot be formed. Patient and functional access survival for this group was comparable with current European data irrespective of vascular access type. Complication rates were acceptably low.
Accepted July 19, 2004
Original Article
Tesio-Caths provide effective and safe long-term vascular access
2 Radiology Department, St Mary's Hospital, London, UK
![]()
Abstract ![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
D. R. Ashby, A. Power, S. Singh, P. Choi, D. H. Taube, N. D. Duncan, and T. D. Cairns Bacteremia Associated with Tunneled Hemodialysis Catheters: Outcome after Attempted Salvage Clin. J. Am. Soc. Nephrol., October 1, 2009; 4(10): 1601 - 1605. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J Kelly The family of vascular access devices Journal of Infection Prevention, September 1, 2009; 10(1_suppl): s7 - s12. [Abstract] [PDF] |
||||
![]() |
J. Ethier, D. C. Mendelssohn, S. J. Elder, T. Hasegawa, T. Akizawa, T. Akiba, B. J. Canaud, and R. L. Pisoni Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study Nephrol. Dial. Transplant., October 1, 2008; 23(10): 3219 - 3226. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Ponticelli New recommendations in the treatment of Gram-positive bacteraemia in dialysis patients Nephrol. Dial. Transplant., January 1, 2008; 23(1): 27 - 32. [Full Text] [PDF] |
||||
![]() |
A. C. Fry, J. Stratton, K. Farrington, K. Mahna, S. Selvakumar, H. Thompson, and P. Warwicker Factors affecting long-term survival of tunnelled haemodialysis catheters a prospective audit of 812 tunnelled catheters Nephrol. Dial. Transplant., January 1, 2008; 23(1): 275 - 281. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Wang, J. M. LaBerge, G. M. Chertow, R. K. Kerlan, M. W. Wilson, and R. L. Gordon Tesio Catheter Access for Long-term Maintenance Hemodialysis Radiology, October 1, 2006; 241(1): 284 - 290. [Abstract] [Full Text] [PDF] |
||||