Skip Navigation


NDT Advance Access originally published online on May 6, 2009
Nephrology Dialysis Transplantation 2009 24(9):2816-2824; doi:10.1093/ndt/gfp207
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
24/9/2816    most recent
gfp207v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Pedrini, L. A.
Right arrow Articles by Ruggiero, P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pedrini, L. A.
Right arrow Articles by Ruggiero, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2009]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Optimization of mid-dilution haemodiafiltration: technique and performance

Luciano A. Pedrini, Annalisa Feliciani, Simona Zerbi, Giorgio Cozzi and Pio Ruggiero

Nephrology and Dialysis Division, Fondazione Orizzonte—Bolognini Hospital, Seriate, Bergamo, Italy

Correspondence and offprint requests to: Luciano A. Pedrini; E-mail: nefrologia.seriate{at}bolognini.bg.it



  Abstract

Background. Mid-dilution haemodiafiltration (MD-HDF), reported as a highly efficient convective-mixed technique, has demonstrated serious drawbacks in relation to the high pressure originating inside the blood compartment of the filter during clinical application. This randomized crossover design study was planned to optimize the efficiency of the MD-HDF technique while reducing its inherent risks.

Methods. Fifteen patients on RRT were submitted in random sequence to standard and reverse MD-HDF under similar operating conditions. Efficiency in solute removal was evaluated by measuring urea (U), phosphate (P) and beta2-microglobulin (β2-m), mean dialysate clearances (KDQ) and eKt/V. Blood and dialysate compartment pressures were monitored on-line during the sessions, and instantaneous hydraulic and membrane permeability indexes were calculated.

Results. During standard MD-HDF sessions, unlike with reverse MD-HDF, excessive blood inlet and transmembrane pressure prevented the planned infusion from being maintained. Resistance index and membrane permeability to water and middle molecules substantially improved with reverse MD-HDF. This resulted in higher β2-m removal (221.3 ± 81.3 versus 185.1 ± 65.5 mg/session, P = 0.007). Phosphate removal was comparable, while U removal was greater with standard MD-HDF (KDQ 272 ± 35 versus 252 ± 29 ml/min, P = 0.002; eKt/V 1.63 ± 0.23 versus 1.49 ± 0.17, P = 0.005).

Conclusions. This study demonstrated the ability of MD-HDF to remove significant amounts of medium-sized uraemic compounds and phosphate, but safe rheologic and hydraulic conditions were only maintained by carrying out treatments with the dialyser used in reverse configuration. For this purpose, the larger MD-220 dialyser ensured better tolerance together with higher middle molecules clearance, even though small molecule removal was slightly worsened. The results of this study may provide some insight into the complex interactions between pressures and flux within the original structure of MD-dialysers and help optimize the clinical application of the technique and reduce its risks.

Keywords: beta2-microglobulin; convective treatments; haemodiafiltration; mid-dilution HDF; transmembrane pressure

Received for publication: 21. 8.08
Accepted in revised form: 15. 4.09


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.