Skip Navigation


NDT Advance Access originally published online on September 5, 2008
Nephrology Dialysis Transplantation 2009 24(2):535-538; doi:10.1093/ndt/gfn512
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
24/2/535    most recent
gfn512v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ponce, P.
Right arrow Articles by Santos, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ponce, P.
Right arrow Articles by Santos, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2008]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Anatomical correlation of a well-functioning access graft for haemodialysis

Pedro Ponce1, Ana Mateus1 and Lidia Santos2

1 Nephrology Department, Hospital Garcia de Orta and Clínica Fresenius Medical Care, Miratejo 2 Nephrology Department, Hospital de Torres Novas, Portugal

Correspondence and offprint requests to: Pedro Ponce, Serviço de Nefro- logia, Hospital Garcia de Orta, Almada, Portugal. Tel: +351-212727248; E-mail: pponce{at}hgo.min-saude.pt



  Abstract

Background. While it is widely accepted that vascular access (VA) haemodynamic surveillance should be performed, its real benefit has not yet been established. In addition, controversy still reigns over pre-emptive angioplasty of detected significant VA stenosis. This pilot study was designed to question the rationale of our decision-making process in VA management.

Methods. All 12 adult patients at our centre, dialyzed through a PTFE graft for over 3 months and meeting the clinical and haemodynamic criteria of a well-functioning VA [dynamic venous pressure (DVP) <150 mmHg and VA flow (Qa) measurement >800 ml/min], were prospectively selected. The selected patients underwent a baseline diagnostic angiogram at consent. No patient was submitted to endovascular intervention, including those with stenosis. Close clinical and haemodynamic follow-up monitoring were maintained over the next 6 months, using monthly Qa measurement through a haematocrit dilution (optodilutional) technique to record any access morbidity.

Results. The baseline diagnostic angiogram of the 12 patients revealed at the venous anastomosis: (i) stenosis reducing >75% of the access lumen in three cases; (ii) stenosis of 50–75% in two cases; (iii) stenosis of 25–50% in four cases and (iv) no stenosis in three cases. One patient with stenosis >75% and another with stenosis between 25 and 50% had graft thromboses during the follow-up period. Neither graft thrombosis could have been predicted from the previous month's Qa evaluation. All four patients with a stenosis >50% and who did not thrombose had a normal Qa at the end of the follow-up period.

Conclusions. Our data suggest that the presence of what we call a significant stenosis does not necessarily correlate with measured Qa and might not be associated with early thrombosis deserving immediate intervention. Further studies are needed to clarify the best surveillance protocol and the role of pre-emptive intervention in significant stenosis.

Keywords: graft surveillance; haemodialysis; stenosis; thrombosis; vascular access flow

Received for publication: 4. 2.08
Accepted in revised form: 20. 8.08


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.