NDT Advance Access originally published online on August 18, 2006
Nephrology Dialysis Transplantation 2006 21(12):3514-3519; doi:10.1093/ndt/gfl424
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure
1Department of Internal Medicine and Nephrology, 2Department of Surgery and 3Department of Radiology, University Hospital Maastricht, Maastricht, The Netherlands
Correspondence and offprint requests to: F. M. van der Sande, MD, PhD, Internist-nephrologist, Department of Internal Medicine and Nephrology, University Hospital Maastricht, P. Debyelaan 25, 6202AZ Maastricht, Maastricht, The Netherlands. Email: fvs{at}groupwise.azm.nl
Background. Vascular access thrombosis is a substantial source of morbidity in chronic haemodialysis patients. Periodical access flow measurements can predict the presence of vascular access stenosis and provide an opportunity for early intervention to prevent subsequent vascular access thrombosis. By this system of quality improvement, vascular access-related costs might be reduced. The aim of this study was to analyse the cost impact of a quality improvement programme based on periodic access flow measurements.
Methods. The number and costs of vascular access interventions (summary of angiography, percutaneous transluminal angioplasty, catheter placement, hospitalization days and costs for surgery) in the period 20012003 (quality improvement period; QIP, 218.6 patient-years observed) were retrospectively compared with a reference period (RP, 19961998, 214.4 patient-years observed) during which no access flow was measured. All access flow measurements were done on a regular base and interventions were performed according to the Kidney Disease Outcome Quality Initiative.
Results. Surgical thrombectomy procedures were significantly less during the QIP (0.25 ± 0.57 events/patient-year) compared with RP (0.63 ± 1.06 events/patient-year; P = 0.000), whereas access loss was not significantly different. During the QIP, 205 radiological interventions were performed (0.88 ± 1.16 events/patient-year), and in the RP around 48 (0.33 ± 0.65 events/patient-year; P = 0.000). Access-related costs tended to be lower during the QIP compared with the RP. The cost reduction appeared to be limited to patients with arteriovenous graft (AVG), in which access-related costs were significantly lower during the QIP (
2360.95 ± 2838.17 patient-year) compared with the RP (
4003.96 ± 3810.92 patient-year; P = 0.012), but not in patients with arteriovenous fistula (AVF).
Conclusion. A quality improvement programme based on periodical access flow measurement reduced the number of acute vascular access failures due to thrombotic events and also significantly reduced health care costs in patients with AVG, but not in patients with AVF. The quality improvement programme had no effect on access survival.
![]()
CiteULike
Connotea
Del.icio.us What's this?
Related articles in NDT:
- Trials and trade-offs in haemodialysis vascular access monitoring
- Talat Alp Ikizler and Jonathan Himmelfarb
NDT 2006 21: 3362-3363.[Extract] [FREE Full Text]
This article has been cited by other articles:
![]() |
P. Ponce, A. Mateus, and L. Santos Anatomical correlation of a well-functioning access graft for haemodialysis Nephrol. Dial. Transplant., February 1, 2009; 24(2): 535 - 538. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. M. Duijm, E. H. Overbosch, Y. S. Liem, R. N. Planken, J. H. M. Tordoir, P. W. M. Cuypers, P. Douwes-Draaijer, and M. W. de Haan Retrograde catheterization of haemodialysis fistulae and grafts: angiographic depiction of the entire vascular access tree and stenosis treatment Nephrol. Dial. Transplant., February 1, 2009; 24(2): 539 - 547. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Tessitore, V. Bedogna, A. Poli, W. Mantovani, G. Lipari, E. Baggio, G. Mansueto, and A. Lupo Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: a controlled cohort study Nephrol. Dial. Transplant., November 1, 2008; 23(11): 3578 - 3584. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Wijnen, F. M. van der Sande, J. H. M. Tordoir, J. P. Kooman, and K. M. L. Leunissen Effect of online haemodialysis vascular access flow evaluation and pre-emptive intervention on the frequency of access thrombosis NDT Plus, October 1, 2008; 1(5): 279 - 284. [Abstract] [Full Text] [PDF] |
||||

