Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kuhlmann, U.
Right arrow Articles by Lange, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuhlmann, U.
Right arrow Articles by Lange, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2001) 16: 1053-1058
© 2001 European Renal Association-European Dialysis and Transplant Association


Technical Report

Accuracy and safety of online clearance monitoring based on conductivity variation

Uwe Kuhlmann1, Rainer Goldau2, Nader Samadi1, Thomas Graf2, Malte Gross2, Giancarlo Orlandini2 and Harald Lange1,

1 Centre of Internal Medicine, Clinic of Nephrology, University of Marburg, Marburg, Germany 2 Fresenius Medical Care, Schweinfurt, Germany

Abstract

Background. Haemodialysis dose has been shown to have a distinct impact upon the morbidity and mortality rate in patients on regular dialysis therapy. Accordingly, the adequacy of dialysis treatment should be guaranteed.

Methods. In 200 dialysis sessions two or three ±10% dialysate conductivity variations were applied to test patient compliance and the accuracy of an electrolyte based online clearance measurement (OCM) reflecting the total clearance of urea.

Results. Using a step profile the electrolytic clearance showed highly significant correlation with the reference data in the blood side (n=118, r=0.867, P<0.001) and dialysate side (n=118, r=0.820, P<0.001) if only reference values were taken into account for which the error in mass balance did not exceed 5%. Kt/V according to the single pool model (n=35, r=0.940, P<0.001), the equilibrated single pool variable volume kinetic model (n=36, r=0.982, P<0.001), Daugirdas formula (n=34, r=0.951, P<0.001) and direct quantification of dialysance via spent dialysate (n=26, r=0.900, P<0.001) showed outstanding correlations with electrolyte-based Kt/V at mass balance error below 5%. No adverse clinical effect of OCM was reported. Serum sodium, body weight, heart rate and breathing rate at rest, arterial pO2 and pCO2 and blood pressure before haemodialysis remained unaffected in OCM measurements in comparison with baseline parameters. A small influx of sodium (1.53±7.62 mmol) into the patient was seen following the impulse, but no signs associated with fluid overload were observed during the study period of 10 consecutive dialysis sessions.

Conclusions. The OCM option of the haemodialysis machine provides a safe and accurate tool for continuous online monitoring of total urea clearance.

Keywords: adequacy of dialysis; conductivity based clearance; haemodialysis; Kt/V; online clearance

Notes

Correspondence and offprint requests to: Prof. Dr H. Lange, Centre of Internal Medicine, Clinic of Nephrology, Philipps-University of Marburg, Baldingerstr, D-35033 Marburg, Germany.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
E. J. Lindley, P. W. Chamney, A. Wuepper, H. Ingles, J. E. Tattersall, and E. J. Will
A comparison of methods for determining urea distribution volume for routine use in on-line monitoring of haemodialysis adequacy
Nephrol. Dial. Transplant., January 1, 2009; 24(1): 211 - 216.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
K. Moret, C. H. Beerenhout, A. W. L. van den Wall Bake, P. G. Gerlag, F. M. van der Sande, K. M. Leunissen, and J. P. Kooman
Ionic dialysance and the assessment of Kt/V: the influence of different estimates of V on method agreement
Nephrol. Dial. Transplant., August 1, 2007; 22(8): 2276 - 2282.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
C. W. McIntyre, S. H. Lambie, M. W. Taal, and R. J. Fluck
Assessment of haemodialysis adequacy by ionic dialysance: intra-patient variability of delivered treatment
Nephrol. Dial. Transplant., March 1, 2003; 18(3): 559 - 562.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.