Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (24)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Karaaslan, H.
Right arrow Articles by Leroux-Robert, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Karaaslan, H.
Right arrow Articles by Leroux-Robert, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2001) 16: 2072-2074
© 2001 European Renal Association-European Dialysis and Transplant Association


Technical Notes

Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis

Hüseyin Karaaslan, Pierre Peyronnet, Daniel Benevent, Christian Lagarde, Michel Rince and Claude Leroux-Robert

Service de Néphrologie, CHU Dupuytren, Avenue Martin Luther King, Limoges, France

Abstract

Background. The indwelling venous catheter such as Dual-Cath® or Twin-Cath® is widely used in haemodialysis. Although the manufacturer recommends filling the catheter lumen with heparin after the dialysis session to prevent clotting, little is known about the systemic effects of such a procedure.

Methods. Twenty haemodialysis patients with Dual-Cath® were studied. Dialysis anticoagulation was achieved by injecting a bolus of dalteparin. The patient/control ratio of activated partial thromboplastin time (aPTT) was determined at the end of the session immediately before and 10 min after locking with 2 ml of undiluted heparin (10 000 U/catheter). We also determined the catheter volume for each patient and measured aPTT immediately before and 10 min after heparin locking with this patient-specific volume. Catheter patency was followed over a 2-week period.

Results. The aPTT values determined at the end of two consecutive dialysis sessions were nearly normal, respectively 1.29 (±0.17) and 1.33 (±0.22), whereas all patients had uncoagulable blood (aPTT >3.75) 10 min after locking with 2 ml of heparin. When catheter volumes were individually calculated, they were found to be substantially lower than 2.0 ml (1.21±0.12 for the arterial branch and 1.27±0.13 for the venous branch). aPTT was only 2.42±0.73 10 min after locking with the estimated volumes except in one patient (aPTT >3.75). No catheter clotting was observed despite these smaller locking volumes.

Conclusions. A risk of inducing serious bleeding does indeed exist with Dual-Cath® heparin locking, especially in postoperative patients. This risk can be reduced by measuring catheter length at the time of placement in order to ensure an appropriate lock volume. Sodium citrate, polygeline, or urokinase are possible alternatives to heparin.

Keywords: indwelling venous haemodialysis catheters; heparin locking

Notes

Correspondence and offprint requests to: Hüseyin Karaaslan, Service de Néphrologie, CHU Dupuytren, Avenue Martin Luther King, F-87000 Limoges, France. Email: karagom{at}free.fr


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
J. Steczko, S. R. Ash, D. E. Nivens, L. Brewer, and R. K. Winger
Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
Nephrol. Dial. Transplant., June 1, 2009; 24(6): 1937 - 1945.
[Abstract] [Full Text] [PDF]


Home page
J Antimicrob ChemotherHome page
K. Sauer, J. Steczko, and S. R. Ash
Effect of a solution containing citrate/Methylene Blue/parabens on Staphylococcus aureus bacteria and biofilm, and comparison with various heparin solutions
J. Antimicrob. Chemother., May 1, 2009; 63(5): 937 - 945.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
I. Markota, D. Markota, and M. Tomic
Measuring of the heparin leakage into the circulation from central venous catheters--an in vivo study
Nephrol. Dial. Transplant., May 1, 2009; 24(5): 1550 - 1553.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. Sungur, E. Eryuksel, S. Yavas, A. Bihorac, A. J. Layon, and L. Caruso
Exit of catheter lock solutions from double lumen acute haemodialysis catheters an in vitro study
Nephrol. Dial. Transplant., December 1, 2007; 22(12): 3533 - 3537.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
M. Allon
Current Management of Vascular Access
Clin. J. Am. Soc. Nephrol., July 1, 2007; 2(4): 786 - 800.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
C. E. Lok, D. Appleton, C. Bhola, B. Khoo, and R. M. A. Richardson
Trisodium citrate 4%--an alternative to heparin capping of haemodialysis catheters
Nephrol. Dial. Transplant., February 1, 2007; 22(2): 477 - 483.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. Grudzinski, P. Quinan, S. Kwok, and A. Pierratos
Sodium citrate 4% locking solution for central venous dialysis catheters--an effective, more cost-efficient alternative to heparin
Nephrol. Dial. Transplant., February 1, 2007; 22(2): 471 - 476.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. J. Flanigan
Melagatran anticoagulation during haemodialysis--'Primum non nocere'
Nephrol. Dial. Transplant., September 1, 2005; 20(9): 1789 - 1790.
[Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
M. C. Weijmer, M. A. van den Dorpel, P. J.G. Van de Ven, P. M. ter Wee, J. A.C.A. van Geelen, J. O. Groeneveld, B. C. van Jaarsveld, M. G. Koopmans, C. Y. le Poole, A. M. Schrander-Van der Meer, et al.
Randomized, Clinical Trial Comparison of Trisodium Citrate 30% and Heparin as Catheter-Locking Solution in Hemodialysis Patients
J. Am. Soc. Nephrol., September 1, 2005; 16(9): 2769 - 2777.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. Agharazii, I. Plamondon, M. Lebel, P. Douville, and S. Desmeules
Estimation of heparin leak into the systemic circulation after central venous catheter heparin lock
Nephrol. Dial. Transplant., June 1, 2005; 20(6): 1238 - 1240.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. C. Weijmer, Y. J. Debets-Ossenkopp, F. J. van de Vondervoort, and P. M. ter Wee
Superior antimicrobial activity of trisodium citrate over heparin for catheter locking
Nephrol. Dial. Transplant., December 1, 2002; 17(12): 2189 - 2195.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.