Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (95)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Sitter, T.
Right arrow Articles by Schiffl, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sitter, T.
Right arrow Articles by Schiffl, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2000) 15: 1207-1211
© 2000 European Renal Association-European Dialysis and Transplant Association

Dialysate related cytokine induction and response to recombinant human erythropoietin in haemodialysis patients

Thomas Sitter, Albrecht Bergner and Helmut Schiffl

Department of Nephrology, Medizinische Klinik Innenstadt, Ludwig-Maximilians-Universität, Munich, Germany

Background. Chronic inflammatory disorders or infections represent a major cause of hyporesponsiveness to recombinant human erythropoietin (rHuEpo). To test the hypothesis that dialysate-related cytokine induction alters the response to rHuEpo, we conducted a prospective study with matched pairs of chronic haemodialysis patients. We compared the effect of two dialysis fluids, differing in their microbiological quality, on the rHuEpo therapy.

Methods. Thirty male patients with end-stage renal disease maintained on regular haemodialysis were assigned either to a group treated with conventional (potentially microbiologically contaminated) dialysate (group I) or to a group treated with online-produced ultrapure dialysate (group II). Randomization was stratified according to the maintenance dose of rHuEpo necessary to maintain a target haemoglobin level of 10–10.5 g/dl. Patients were followed for 12 months. Kt/V was calculated by the formula of Daugirdas. Haemoglobin levels were measured weekly and serum ferritin concentrations were determined at 6-week intervals. C-reactive protein (CRP) and interleukin-6 (IL-6) was measured by an ELISA at the start of the study and after 3, 6 and 12 months.

Results. In group I, continuous use of bicarbonate dialysate did not change the rHuEpo dosage given to achieve the target haemoglobin level and was associated with elevated surrogate markers (CRP, IL-6) of cytokine-induced inflammation. The switch from conventional to online-produced ultrapure dialysate in group II resulted in a lower bacterial contamination with a significant decrease of CRP and IL-6 blood levels. It was accompanied by a significant and sustained reduction of the rHuEpo dosage, which was required to correct the anaemia. Using multiple regression analysis, IL-6 levels are shown to have a strong predictive value for rHuEpo dosage in both groups.

Conclusions. Our data demonstrate that dialysate-related factors such as low bacterial contamination can induce the activation of monocytes, resulting in elevated serum levels of IL-6. Dialysate-related cytokine induction might diminish erythropoiesis. The use of pyrogen free ultrapure dialysate resulted in a better response to rHuEpo. Not only would it save money, but it would also help to maintain an optimal haemoglobin level without further increase in rHuEpo dosage.

Keywords: biocompatibility; erythropoietin; interleukin-6; renal anaemia; ultrapure dialysate

Correspondence and offprint requests to: Professor Dr H. Schiffl, Medizinische Klinik der LMU, Ziemssenstr. 1, D-80336 München, Germany.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
G. Glorieux, E. Schepers, R. Schindler, H.-D. Lemke, F. Verbeke, A. Dhondt, N. Lameire, and R. Vanholder
A novel bio-assay increases the detection yield of microbiological impurity of dialysis fluid, in comparison to the LAL-test
Nephrol. Dial. Transplant., February 1, 2009; 24(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
NDT PlusHome page
A. L. M. de Francisco, P. Stenvinkel, and S. Vaulont
Inflammation and its impact on anaemia in chronic kidney disease: from haemoglobin variability to hyporesponsiveness
NDT Plus, January 1, 2009; 2(suppl_1): i18 - i26.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
K. E. Jie, M. C. Verhaar, M.-J. M. Cramer, K. van der Putten, C. A. J. M. Gaillard, P. A. Doevendans, H. A. Koomans, J. A. Joles, and B. Braam
Erythropoietin and the cardiorenal syndrome: cellular mechanisms on the cardiorenal connectors
Am J Physiol Renal Physiol, November 1, 2006; 291(5): F932 - F944.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. M. Lamas, M. Alonso, F. Sastre, G. Garcia-Trio, J. Saavedra, and L. Palomares
Ultrapure dialysate and inflammatory response in haemodialysis evaluated by darbepoetin requirements--a randomized study
Nephrol. Dial. Transplant., October 1, 2006; 21(10): 2851 - 2858.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
D. L. Regidor, J. D. Kopple, C. P. Kovesdy, R. D. Kilpatrick, C. J. McAllister, J. Aronovitz, S. Greenland, and K. Kalantar-Zadeh
Associations between Changes in Hemoglobin and Administered Erythropoiesis-Stimulating Agent and Survival in Hemodialysis Patients
J. Am. Soc. Nephrol., April 1, 2006; 17(4): 1181 - 1191.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
V. Panichi, G. Manca-Rizza, S. Paoletti, D. Taccola, C. Consani, C. Filippi, E. Mantuano, A. Sidoti, G. Grazi, A. Antonelli, et al.
Effects on inflammatory and nutritional markers of haemodiafiltration with online regeneration of ultrafiltrate (HFR) vs online haemodiafiltration: a cross-over randomized multicentre trial
Nephrol. Dial. Transplant., March 1, 2006; 21(3): 756 - 762.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
R. A. Ward
Protein-Leaking Membranes for Hemodialysis: A New Class of Membranes in Search of an Application?
J. Am. Soc. Nephrol., August 1, 2005; 16(8): 2421 - 2430.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. J. Collins, J. Liu, and J. P. Ebben
Dialyser reuse-associated mortality and hospitalization risk in incident Medicare haemodialysis patients, 1998-1999
Nephrol. Dial. Transplant., May 1, 2004; 19(5): 1245 - 1251.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. C. Cooper, C. P. Breen, B. Vyas, J. Ochola, D. M. Kemeny, and I. C. Macdougall
Poor response to recombinant erythropoietin is associated with loss of T-lymphocyte CD28 expression and altered interleukin-10 production
Nephrol. Dial. Transplant., January 1, 2003; 18(1): 133 - 140.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
F. Locatelli, L. D. Vecchio, and S. Andrulli
The modality of dialysis treatment: does it influence the response to erythropoietin treatment?
Nephrol. Dial. Transplant., October 1, 2001; 16(10): 1971 - 1974.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Kato, M. Odamaki, T. Takita, M. Furuhashi, Y. Maruyama, and A. Hishida
High blood soluble receptor p80 for tumour necrosis factor-{alpha} is associated with erythropoietin resistance in haemodialysis patients
Nephrol. Dial. Transplant., September 1, 2001; 16(9): 1838 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
H. Schiffl, S. M. Lang, D. Stratakis, and R. Fischer
Effects of ultrapure dialysis fluid on nutritional status and inflammatory parameters
Nephrol. Dial. Transplant., September 1, 2001; 16(9): 1863 - 1869.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.