Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (58)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Rodriguez, J. A.
Right arrow Articles by Piera, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rodriguez, J. A.
Right arrow Articles by Piera, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2000) 15: 402-408
© 2000 European Renal Association-European Dialysis and Transplant Association

The function of permanent vascular access

Juan A. Rodriguez, Luis Armadans, Eugenio Ferrer, Antonio Olmos, Salvador Codina, Jorge Bartolomé, Javier Borrellas and Luis Piera

Hospital General Universitario Vall d'Hebron, Servicio de Nefrologia, Barcelona, Spain

Correspondence and offprint requests to: J. A. Rodriguez, Hospital General de la Vall d'Hebron, Servicio de Nefrologia, Psg. Vall d'Hebron 119–129, E-08035 Barcelona, Spain.

Background. Complications arising from vascular access (VA) are major causes of morbidity in patients on renal replacement therapy (RRT). They contribute to frustration of health care providers and to high medical cost. To prevent failures in the future it will be helpful to identify the factors that are related to VA malfunction.

Methods. In a retrospective analysis we analysed the types, duration and primary rate of patency of 1033 permanent vascular accesses in 544 consecutive patients established during a 13-year period in a tertiary care hospital. Patient characteristics, incidence, and risk factors related to VA failure were registered. In addition, VA outcomes in patients who started haemodialysis with a catheter and in whom initial VA failure occurred were analysed separately.

Results. Forty-five per cent of patients required a central catheter at the start of HD, but 92% of them were being dialysed with an a-v fistula at the last observation. The total number of complications was 0.24 episodes per patient per year at risk and the rate of thrombosis 0.1. A total of 52% of patients were dialysed throughout the observation period with their initial a-v fistula; 9.3% had more than three episodes of VA failure. The radiocephalic a-v fistula was the VA with the best median duration, exceeding 7 years, but also the type that had the highest initial failure rate, i.e. 25% of patients and 13% of the events. The brachiocephalic a-v fistula was the second most frequent type of VA, with a median duration of function of 3.6 years, in contrast to the humerobasilic a-v fistula, which exceeded 5 years. Average patency of the different types of grafts did not exceed 1 year, with the exception of the autologous saphenous graft with a median duration of function of 1.4 years. Patients with glomerulonephritis had the best function rates for their VA, the median exceeding the duration of the study, whereas in half of the diabetic patients it was less than 1 year. The duration of patency of the VA was twice in patients below age 65 years and in elderly males compared to elderly females. Patients who started HD with a catheter, as well as those with initial VA failure, had a higher rate of VA failure in the subsequent course on RRT.

Conclusion. The radiocephalic and the humerobasilic a-v fistulae are the two types of VA with the longest duration of function, although a high rate of initial failure is seen with the radiocephalic a-v fistula. Age, female gender, presence of diabetic nephropathy, start of dialysis with a catheter, and failure to wait for initial maturation of the VA are risk factors, and account for the majority of VA failures during RRT.

Keywords: end-stage renal disease; haemodialysis; renal replacement therapy; vascular access


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
E. B. Malinzak and T. J. Gan
Regional Anesthesia for Vascular Access Surgery
Anesth. Analg., September 1, 2009; 109(3): 976 - 980.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. S. Hammes, M. E. Boghosian, K. W. Cassel, B. Funaki, and F. L. Coe
Characteristic differences in cephalic arch geometry for diabetic and non-diabetic ESRD patients
Nephrol. Dial. Transplant., July 1, 2009; 24(7): 2190 - 2194.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Perez-Garcia, A. Martin-Malo, J. Fort, X. Cuevas, F. Llados, J. Lozano, F. Garcia, and on behalf of all Investigators from the ANSWER stu
Baseline characteristics of an incident haemodialysis population in Spain: results from ANSWER--a multicentre, prospective, observational cohort study
Nephrol. Dial. Transplant., February 1, 2009; 24(2): 578 - 588.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
T. Hasegawa, S. J. Elder, J. L. Bragg-Gresham, R. L Pisoni, S. Yamazaki, T. Akizawa, M. Jadoul, R. C. Hugh, F. K Port, and S. Fukuhara
Consistent Aspirin Use Associated with Improved Arteriovenous Fistula Survival among Incident Hemodialysis Patients in the Dialysis Outcomes and Practice Patterns Study
Clin. J. Am. Soc. Nephrol., September 1, 2008; 3(5): 1373 - 1378.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. W. I. Clark, R. A. Cohen, A. Kwak, J. F. Markmann, S. W. Stavropoulos, A. A. Patel, M. C. Soulen, J. I. Mondschein, S. Kobrin, R. D. Shlansky-Goldberg, et al.
Salvage of Nonmaturing Native Fistulas by Using Angioplasty
Radiology, December 1, 2006; 242(1): 286 - 292.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Momose, M. Tsushima, H. Mizuno, S. Kajihara, H. Saitoh, T. Mikuni, Y. Tonosaki, T. Kazi, and T. Funyu
Impact of upper extremity abduction on arteriovenous fistula (AVF) blood flow
Nephrol. Dial. Transplant., July 1, 2006; 21(7): 2033 - 2034.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Saran, D. M. Dykstra, R. L. Pisoni, T. Akiba, T. Akizawa, B. Canaud, K. Chen, L. Piera, A. Saito, and E. W. Young
Timing of first cannulation and vascular access failure in haemodialysis: an analysis of practice patterns at dialysis facilities in the DOPPS
Nephrol. Dial. Transplant., September 1, 2004; 19(9): 2334 - 2340.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. K. Rajan, S. Bunston, S. Misra, R. Pinto, and C. E. Lok
Dysfunctional Autogenous Hemodialysis Fistulas: Outcomes after Angioplasty--Are There Clinical Predictors of Patency?
Radiology, August 1, 2004; 232(2): 508 - 515.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Magnasco, G. Bacchini, A. Cappello, V. La Milia, B. Brezzi, P. Messa, and F. Locatelli
Clinical validation of glucose pump test (GPT) compared with ultrasound dilution technology in arteriovenous graft surveillance
Nephrol. Dial. Transplant., July 1, 2004; 19(7): 1835 - 1841.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
C. Basile, G. Ruggieri, L. Vernaglione, A. Montanaro, and R. Giordano
The natural history of autogenous radio-cephalic wrist arteriovenous fistulas of haemodialysis patients: a prospective observational study
Nephrol. Dial. Transplant., May 1, 2004; 19(5): 1231 - 1236.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. A. E. Turmel-Rodrigues and P. Bourquelot
Prospective evaluation of failure modes in autogenous radiocephalic access for haemodialysis: good diagnostic tools are necessary for effective multimodal treatments and autogenous elbow fistulas must not be ignored
Nephrol. Dial. Transplant., December 1, 2003; 18(12): 2681 - 2681.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
P. Wiese, J. Blume, H.-J. Mueller, H. Renner, and a. B. Nonnast-Daniel
Clinical and Doppler ultrasonography data of a polyurethane vascular access graft for haemodialysis: a prospective study
Nephrol. Dial. Transplant., July 1, 2003; 18(7): 1397 - 1400.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
C. E. Lok, C. Bhola, R. Croxford, and R. M.A. Richardson
Reducing vascular access morbidity: a comparative trial of two vascular access monitoring strategies
Nephrol. Dial. Transplant., June 1, 2003; 18(6): 1174 - 1180.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. Turmel-Rodrigues, A. Mouton, B. Birmele, L. Billaux, N. Ammar, O. Grezard, S. Hauss, and J. Pengloan
Salvage of immature forearm fistulas for haemodialysis by interventional radiology
Nephrol. Dial. Transplant., December 1, 2001; 16(12): 2365 - 2371.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Vanholder
Vascular access: care and monitoring of function
Nephrol. Dial. Transplant., August 1, 2001; 16(8): 1542 - 1545.
[Full Text] [PDF]


Home page
RadiologyHome page
S. O. Trerotola and L. A. Turmel-Rodrigues
Off the Beaten Path: Transbrachial Approach for Native Fistula Interventions
Radiology, March 1, 2001; 218(3): 617 - 619.
[Full Text]


Home page
Nephrol Dial TransplantHome page
L. Turmel-Rodrigues, J. Pengloan, S. Baudin, D. Testou, M. Abaza, G. Dahdah, A. Mouton, and D. Blanchard
Treatment of stenosis and thrombosis in haemodialysis fistulas and grafts by interventional radiology
Nephrol. Dial. Transplant., December 1, 2000; 15(12): 2029 - 2036.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.