NDT Advance Access originally published online on April 3, 2008
Nephrology Dialysis Transplantation 2008 23(9):2884-2888; doi:10.1093/ndt/gfn186
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
A formula to predict corrected calcium in haemodialysis patients
1 Division of Nephrology, Department of Medicine 2 Department of Epidemiology and Biostatistics, University of Western Ontario, London Health Sciences Centre, London, UK 3 Division of Endocrinology and Metabolism, University of Calgary, Canada
Correspondence and offprint requests to: Arsh Jain, Division of Nephrology, Department of Medicine, Epidemiology and Biostatistics, University of Western Ontario, London Health Sciences Centre, London, UK. Tel: +44-519-685-8500 Ext 55726; Fax: +44-519-685-8072; E-mail: arsh.jain{at}utoronto.ca
| Abstract |
|---|
|
|
|---|
Background. The conventional calcium correction formula (corrected total calcium (mmol/L) = TCa (mmol/L) + 0.02 [40 (g/L) – albumin (g/L)]) is broadly applied for the estimation of serum calcium in haemodialysis (HD) patients, despite the fact that it was not derived or validated in a HD population. A novel formula was derived and validated for corrected serum calcium in HD patients.
Methods. Total calcium (TCa), ionized calcium (iCa2+), magnesium, phosphate, albumin and bicarbonate were collected from 60 HD patients to derive the formula. A validation set of 237 stable HD patients was then examined, and subjects were classified as hyper-, hypo- and normocalcaemic based on the iCa2+. Agreement of the new formula was calculated with iCa2+ as the gold standard, using the intraclass correlation coefficient (ICC). This was compared to the agreement between iCa2+ and the following: uncorrected total serum calcium (TCa), the conventional correction formula, the Orrell formula and the Clase formula.
Results. Using multiple linear regression the following formula was derived: corrected total calcium (mmol/L) = TCa (mmol/L) + 0.01 [30 (g/L) – albumin (g/L)]. The new formula had superior agreement compared to all of the other formulae. There was a statistically significant greater agreement between the new formula and the iCa2+ as compared to the conventional formula (P < 0.01). However, the new formula did not significantly outperform the Orrell formula, the Clase formula or Total calcium.
Conclusions. The use of our simple new formula should enable more appropriate decision making compared to the conventional formula in the highly complex HD population.
Keywords: corrected calcium; haemodialysis; ionized calcium; serum calcium
| Introduction |
|---|
|
|
|---|
Calcium regulation and homeostasis are important in the clinical management of patients with end-stage renal disease on haemodialysis (HD). Both hyper- and hypocalcaemia have been identified as independent predictors of mortality in HD patients [1,2]. However, measuring a serum calcium level is not as easy as it may first seem; while total serum calcium (TCa) can be measured, it is the ionized fraction which is not protein bound that is biologically active. Ionized calcium (iCa2+) is neither easily nor routinely measured in all laboratories. Thus a number of formulae have been derived to estimate the iCa2+ or the corrected total calcium (TCacorr) from TCa [3–10].
Clinical practice guidelines suggest that corrected calcium be targeted in the low normal range for patients on HD [11]. The guidelines unfortunately do not state which calcium correcting equation should be used.
The medical community has embraced a formula for calcium correction based on an article published in the British Medical Journal by an anonymous author in 1977 [12]. This correction formula, TCacorr = TCa (mmol/L)+ 0.02 [40 (g/L) – albumin (g/L)], was a crude simplification combining seven previous publications, although it is often incorrectly attributed to Payne et al. [8]. This formula has been applied ubiquitously in health care, and is referaenced in numerous medical textbooks and journals [13–15]. Of note, Payne's original study excluded patients from the renal medicine department [8]. Numerous authors have demonstrated the poor performance of the Payne formula and other correction formulae, particularly when applied to HD patients, compared to the gold standard of iCa2+ [4,16–18]. Yet, the conventional formula continues to be applied broadly for the estimation of calcium exposure in HD patients. Developing a simple and accurate estimate of corrected serum calcium in this patient population was highly desirable.
The objective of this study, therefore, was to derive and subsequently validate a novel and simple formula to estimate corrected TCa in HD patients. A gold standard of iCa+2 was compared to our new formula, as well as to the conventional correction formula, uncorrected TCa, Orrell formula and Clase formula. We hypothesized that our new formula would outperform the conventional formula.
| Subjects and methods |
|---|
|
|
|---|
This experiment was divided into two parts following suggested guidelines for the development of clinical prediction rules [19]. The first was the derivation of a new formula for corrected serum calcium and second was the validation of the new formula in an independent data set.
Patients and sample analysis
Blood samples were collected from 297 chronic stable HD outpatients at three tertiary care hospitals. The derivation set comprised 60 patients from London Health Sciences Centre, University Campus, London, Canada. The validation set comprised 237 patients from St. Joseph's Health Centre and London Health Sciences Centre, Westminster Campus, London, Canada. Samples were collected pre-dialysis on days of routine monthly biochemical testing. Arterialized venous blood was collected without a tourniquet from the patient's fistula or graft. If the patient had a tunnelled heparin-primed catheter, an initial sample of blood equal to or greater than the volume of the catheter was discarded to avoid contamination. All blood was collected in lithium heparin tubes. Plasma was used for sodium, potassium, phosphate, magnesium, albumin and TCa measurements and whole blood was used for iCa2+, pH and total CO2 (HCO–3). Samples for iCa2+ were transported anaerobically and on ice if they were not going to be tested within 20 min. The iCa2+ was measured using the ion-selective electrode method. The quoted laboratory reference range for iCa2+ is 1.09–1.30 mmol/L and the between day coefficient of variation (CV) ranged from 1.1 to 3.3%. The bromcresol purple (BCP) dye-binding assay was performed on fresh plasma for albumin measurements. Both total calcium and albumin were measured using the LX20 Beckman Coulter analyser. The quoted laboratory reference range for albumin is 35–50 g/L and the between day CV was 1.4–1.7% and for TCa is 2.12–2.62 mmol/L and the between day CV was 1.21–1.29%.
Statistical analysis
Using the derivation set (n = 60), stepwise multiple linear regression with backward elimination was performed to determine the effect of the potential explanatory variables TCa, albumin, phosphate, magnesium and bicarbonate on iCa2+. For purposes of simplification, we assumed that the TCacorr was equal to twice the iCa2+ as has been considered by others [4,10,20]. Thus the dependent variable was (2 x iCa2+). Subjects were classified as hyper-, hypo- and normocalcaemic based on the iCa2+ reference range.
As physicians, we are more interested in the degree to which a patient deviates from the norm rather than whether a measure correctly dichotomizes a patient as being normal or abnormal. Thus, to assess the agreement between the gold standard and the various formulae we followed the methodology of Clase et al. [4]. To directly compare iCa2+ with the formula-based values we first needed to normalize the data. In order to do this we first assumed that the normal ranges (iCa2+: 1.09–1.30 mmol/L; TCa: 2.12– 2.62 mmol/L) represented the respective 95% confidence interval [i.e. mean ± 1.96 standard deviations (SD)]. Each measure was then converted to a z-score zCa = (Cameasured – mean)/SD. The z-scores were then compared to assess how extreme each measure was from the mean/normal range. We then used intraclass correlation coefficient (ICC) to assess the level of agreement between each of the formulae and iCa2+. ICCs were compared following methodology described by Donner et al. [21] for testing the equality of dependent ICCs. We also present data on the number of patients who were misclassified for each of the formulae tested. We present a summation of both the false negatives and false positives for each formula using iCa2+ as the gold standard. This value is then converted to a percentage to give us the percent disagreement (or 100% – percent agreement).
All analyses were performed using SPSS 11.0 statistical software (SPSS, Inc., Chicago, IL, USA) and SAS version 9.0 (SAS Institute, Cary, NC, USA).
| Results |
|---|
|
|
|---|
Derivation
In the original model total calcium, albumin, magnesium and phosphate were significantly associated with the dependent variable at P < 0.05. The numeric contribution of phosphate and magnesium to the equation was small, and for the sake of parsimony, a model excluding these two variables was constructed. The final regression equation was (2 x iCa2+) = 0.18 + 1.038 (TCa) – 0.0093 (albumin) (see Table 1).
|
Using means for values of TCa and albumin from the derivation set and forcing them into the model, the formula was then simplified algebraically into the final model: TCacorr (mmol/L) = TCa (mmol/L) + 0.01 [30 (g/L) – albumin (g/L)].
Validation
The mean values and ranges for iCa2+, TCa and albumin in the 237 subjects comprising the validation set are summarized in Table 2. The point-prevalence of hypercalcaemia in the validation set, defined as iCa2+ >1.30 mmol/L, was 5.4%. The point-prevalence of hypocalcaemia, defined as iCa2+ <1.09 mmol/L, was 27%.
|
The ICCs for the formulae compared with iCa2+ are as shown in Table 3. The ICC was highest with the new formula with a value of 0.689 and was fairly poor for the conventional formula 0.480 [22]. However the Orrell formula, Clase formula and uncorrected total calcium preformed fairly well, with ICCs of 0.668, 0.642 and 0.642, respectively. No other estimator was noted to perform better than the new formula. When assessing percent disagreement the new formula continued to outperform the other formulae as seen in Table 4.
|
|
The correlation for the conventional formula with iCa2+ was significantly lower than the new formula (P < 0.01). However, the new formula did not significantly outperform the Orrell formula, the Clase formula or the uncorrected total calcium.
| Discussion |
|---|
|
|
|---|
Since the first algorithm by McLean and Hastings in 1935 [23] that predicted a corrected iCa2+ from total calcium and protein, numerous formulae have followed in an attempt to improve this estimation [3–10]. A significant relationship between albumin and serum calcium has been reported [3,7,8] and therefore many formulae have adjusted total calcium for albumin. Of the various formulae to date, the crude modification formula, TCacorr (mmol/L) = TCa (mmol/L) + 0.02 [40 (g/L) – alb (g/L)], has been the most widely applied [8]. It continues to appear in the medical literature, including the discipline of nephrology, despite the lack of validation in populations with advanced renal disease. Goransson et al. have suggested the abandonment of albumin correct Ca measurements due to its poor performance as compared to the gold standard or iCa2+ [24]. However, until iCa2+ calcium can be measured without a significant impact on resources this may not be widely adopted.
We derived a simple formula, TCacorr (mmol/L) = TCa (mmol/L) + 0.01 [30 (g/L) – albumin (g/L)], to estimate the calcium level in HD patients, using a derivation set of 60 HD patients. We subsequently validated our formula in an independent set of 237 HD patients, and demonstrated superiority over the conventional correction formula, as well as a suggestion of increased performance as compared with the Orrell formula, the Clase formula and the uncorrected TCa. Agreement was greatest between the gold standard and our new formula. Given the varied ranges of normal for iCa2+ at different centres [4,24], we preformed a sensitivity analysis with an alternate reference range for iCa2+ (1.15–1.35 mmol/l). The new formula continued to outperform all other formulae. In fact with this reference range, it was found to have significantly greater agreement with the gold standard than the conventional formula as well as the Clase formula.
We chose the iCa2+ as the gold standard and not pH corrected iCa2+. Much of the recent literature on this subject has suggested that there is significant degree of metabolic acidosis in the dialysis patient. Thus correcting for pH will underestimate the true concentrations of iCa2+ [4,24].
With specific reference to the HD population, the applicability of existing correction formulae has increasingly come into question. This population is unique in that patients are often hypoalbuminaemic and subject to altered calcium homeostasis [25,26]. Clase et al. reviewed the performance of various correction strategies in HD patients [4]. Of the four formulae examined, only the Orrell formula provided a superior prediction of iCa2+ than the uncorrected TCa. Two of the formulae, including the original unsimplified Payne formula, consistently overestimated iCa2+ while the formula by Orrell et al. [7] tended to overestimate iCa2+ at low albumin levels and underestimate iCa2+ at high albumin levels. Our novel formula outperformed the conventional correction formula, the uncorrected TCa as well as the Orrell and Clase formulae.
It is interesting to note that, as in our study, other studies have shown that uncorrected TCa agrees well with iCa2+. A review by Ladenson et al. among variety of patients found that, of 13 published formulae that corrected TCa for protein, albumin and pH, none, including the original Payne formula, performed any better than the uncorrected TCa alone [16]. Our study, as well as Clase et al., found that uncorrected total serum agrees with iCa2+ to a degree that is similar to other correction formulae. This brings into question the need to correct for albumin at all. Particularly, considering that the ICC for uncorrected total serum was not significantly different from the best performing formulae.
Varying degrees of hypoalbuminemia in the HD population may be one contributor to the inaccuracy of previous correction formulae. In fact, Payne and others have suggested that their formulae may be unreliable in low albumin states such as nephrotic syndrome or at extremes of calcium ranges [3,9,27,28]. There is an inverse relationship between the amount of calcium bound to non-albumin proteins and serum albumin levels [29]. Specifically, there is a greater proportion of calcium bound to non-albumin binding proteins as albumin levels fall [9]. Formulae derived from patients within a narrow range of albumin levels would likely overestimate the correction for low albumin by failing to account for this increased affinity of calcium to non-albumin proteins. Hence, these formulae will tend to overestimate calcium in hypoalbuminemic states such as renal failure.
Our formula also provides a methodological advantage over previous formulae in that BCP staining was used to measure albumin versus bromcresol green (BCG). Reported difficulties with the use of BCG include non-specific binding with globulins, and falsely elevated albumin levels in serum samples containing heparin or fibrinogen [30–32]. Also, a few studies have demonstrated the difficulties of measuring albumin using BCP in specific clinical situations [33,34]. However, two large studies in HD patients that compared albumin measurements by BCP and BCG with the gold standards of nephelometry and immunoturbidimetry found better correlation of BCP with the respective gold standards [35,36]. Carfey et al. showed that the use of BCG resulted in systematic overestimation of albumin in HD patients, with the greatest discrepancies seen in hypoalbuminaemic HD patients [36]. Increased non-specific binding of other proteins to BCG in uraemic patients was suggested as a possible explanation for the error. Clase et al. have suggested a correction formula, based on 50 stable HD patients [4]. These investigators used BCG to measure albumin, which may explain the poorer performance in our validation set.
| Conclusion |
|---|
|
|
|---|
The correction formula for serum calcium TCacorr (mmol/L) = TCa (mmol/L) + 0.02 [40 (g/L) – albumin (g/L)] [8], which is currently in widespread use, has very poor agreement with the gold standard of iCa2+ in HD patients. None of the currently available formulae have been both derived and subsequently validated in the HD population. Our novel formula, TCacorr (mmol/L) = TCa (mmol/L) + 0.01 [30 (g/L) – albumin (g/L)], independently derived and validated in HD patients for the correction of serum calcium for albumin, results in significantly better agreement with iCa2+ compared to the conventional formula. Although not significantly, our formula performs better than the Orrell formula, the Clase formula, as well as uncorrected TCa. We recommend that the use of the conventional correction formula be abandoned in HD patients, and suggest that the use of our novel and simple formula for calcium correction will enable more appropriate decision making in this highly complex population.
| Acknowledgments |
|---|
We would like to thank the editors, reviewers, Dr Amit X Garg and Dr G Y Zou, for their useful advice and feedback on the manuscript.
Conflict of interest statement. None declared.
| References |
|---|
|
|
|---|
- Foley RN, Parfrey PS, Harnett JD, et al. Hypocalcemia, morbidity, and mortality in end-stage renal disease. Am J Nephrol (1996) 16:386–393.[Web of Science][Medline]
- Lowrie EG, Lew NL. Death risk in hemodialysis patients: the predictive value of commonly measured variables and an evaluation of death rate differences between facilities. Am J Kidney Dis (1990) 15:458–482.[Web of Science][Medline]
- Berry EM, Gupta MM, Turner SJ, et al. Variation in plasma calcium with induced changes in plasma specific gravity, total protein, and albumin. Br Med J (1973) 4:640–643.
[Abstract/Free Full Text] - Clase CM, Norman GL, Beecroft ML, et al. Albumin-corrected calcium and ionized calcium in stable haemodialysis patients. Nephrol Dial Transplant (2000) 15:1841–1846.
[Abstract/Free Full Text] - Gardner MD, Dryburgh FJ, Fyffe JA, et al. Predictive value of derived calcium figures based on the measurement of ionised calcium. Ann Clin Biochem (1981) 18(Pt 2):106–109.[Web of Science][Medline]
- Marshall RW, Hodgkinson A. Calculation of plasma ionised calcium from total calcium, proteins and pH: comparison with measured values. Clin Chim Acta (1983) 127:305–310.[CrossRef][Web of Science][Medline]
- Orrell DH. Albumin as an aid to the interpretation of serum calcium. Clin Chim Acta (1971) 35:483–489.[CrossRef][Web of Science][Medline]
- Payne RB, Little AJ, Williams RB, et al. Interpretation of serum calcium in patients with abnormal serum proteins. Br Med J (1973) 4:643–646.
[Abstract/Free Full Text] - Pedersen KO. An analysis of measured and calculated calcium quantities in serum. Scand J Clin Lab Invest (1978) 38:659–667.[CrossRef][Web of Science][Medline]
- Ring T, Halkier P, Hansen HH, et al. Calcium in patients on hemodialysis. Clin Nephrol (1995) 43:332–334.[Web of Science][Medline]
- Eknoyan G, Levin A, Levin N. Bone metabolism and disease in chronic kidney disease. Am J Kidney Dis (2003) 42(Suppl S3):1–202.
- Anonymous. Correcting the calcium. Br Med J (1977) 1:598.[Medline]
- Brenner BM, Rector FC. The Kidney (1981) 2nd edn. Philadelphia: Saunders.
- Gohda T, Shou I, Fukui M, et al. Parathyroid hormone gene polymorphism and secondary hyperparathyroidism in hemodialysis patients. Am J Kidney Dis (2002) 39:1255–1260.[CrossRef][Web of Science][Medline]
- Yonemura K, Fujimoto T, Fujigaki Y, et al. Vitamin D deficiency is implicated in reduced serum albumin concentrations in patients with end-stage renal disease. Am J Kidney Dis (2000) 36:337–344.[CrossRef][Web of Science][Medline]
- Ladenson JH, Lewis JW, Boyd JC. Failure of total calcium corrected for protein, albumin, and pH to correctly assess free calcium status. J Clin Endocrinol Metab (1978) 46:986–993.
[Abstract/Free Full Text] - Pain RW, Rowland KM, Phillips PJ, et al. Current corrected calcium concept challenged. Br Med J (1975) 4:617–619.
[Abstract/Free Full Text] - Ryan GD, Masarei JR. Validity of corrected calcium values. Clin Chim Acta (1979) 91:329–335.[CrossRef][Web of Science][Medline]
- McGinn TG, Guyatt GH, Wyer PC, et alEvidence-Based Medicine Working Group. Users guides to the medical literature: XXII: how to use articles about clinical decision rules. JAMA (2000) 284:79–84.
[Abstract/Free Full Text] - Carney SL. Ionized calcium concentration in maintenance hemodialysis patients. Clin Nephrol (1992) 38:167–170.[Web of Science][Medline]
- Donner A, Zou G. Testing the equality of dependent intraclass correlation coefficients. The Statistician (2002) 51(3):367–379.
- Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics (1977) 33:159–174.[CrossRef][Web of Science][Medline]
- McLean FC, Hastings AB. The state of calcium in the fluids of the body. J Biol Chem (1935) 108:285–322.
[Free Full Text] - Goransson LG, Skadberg O, Bergrem H. Albumin-corrected or ionized calcium in renal failure? What to measure? Nephrol Dial Transplant (2005) 20:2126–2129.
[Abstract/Free Full Text] - Tamm HS, Nolph KD, Maher JF. Factors affecting plasma calcium concentration during hemodialysis. Arch Intern Med (1971) 128:769–773.
[Abstract/Free Full Text] - Furszyfer J, Goldsmith RS, Johnson WJ. Control of secondary hyperparathyroidism during long term hemodialysis. Proc Cen Soc Clin Res (1970) 43:119.
- Conceicao SC, Weightman D, Smith PA, et al. Serum ionised calcium concentration: measurement versus calculation. Br Med J (1978) 1:1103–1105.
[Abstract/Free Full Text] - Payne RB, Little AJ, Williams RB, et al. Letter: correction of plasma calcium measurements. Br Med J (1974) 1:393.
[Free Full Text] - Besarab A, Caro JF. Increased absolute calcium binding to albumin in hypoalbuminaemia. J Clin Pathol (1981) 34:1368–1374.
[Abstract/Free Full Text] - Gustaffson JEC. Improved specificity of serum albumin determination and estimation of acute phase reactants by the use of the bromocresol green reaction. Clin Chem (1976) 37:766–768.
- Hallbach J, Hoffmann GE, Guder WG. Overestimation of albumin in heparinized plasma. Clin Chem (1991) 37:566–568.
[Abstract/Free Full Text] - Webster D, Bignell AH, Attwood EC. An assessment of the suitability of bromocresol green for the determination of serum albumin. Clin Chim Acta (1974) 53:101–108.[CrossRef][Web of Science][Medline]
- Bush V, Reed RG. Bromcresol purple dye-binding methods underestimate albumin that is carrying covalently bound bilirubin. Clin Chem (1987) 33:821–823.
[Abstract/Free Full Text] - Mabuchi H, Nakahashi H. Underestimation of serum albumin by the bromcresol purple method and a major endogenous ligand in uremia. Clin Chim Acta (1987) 167:89–96.[CrossRef][Web of Science][Medline]
- Blagg CR, Liedtke RJ, Batjer JD, et al. Serum albumin concentration-related health care financing administration quality assurance criterion is method-dependent: revision is necessary. Am J Kidney Dis (1993) 21:138–144.[Web of Science][Medline]
- Carfray A, Patel K, Whitaker P, et al. Albumin as an outcome measure in haemodialysis in patients: the effect of variation in assay method. Nephrol Dial Transplant (2000) 15:1819–1822.
[Abstract/Free Full Text]
Accepted in revised form: 10. 3.08
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
L. Labriola, P. Wallemacq, B. Gulbis, and M. Jadoul The impact of the assay for measuring albumin on corrected ('adjusted') calcium concentrations Nephrol. Dial. Transplant., June 1, 2009; 24(6): 1834 - 1838. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
