Skip Navigation



NDT Advance Access published online on November 5, 2009

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfp577
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Saucy, F.
Right arrow Articles by Corpataux, J.-M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saucy, F.
Right arrow Articles by Corpataux, J.-M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Is intra-operative blood flow predictive for early failure of radiocephalic arteriovenous fistula?

François Saucy1, Erik Haesler2, Claude Haller1, Sébastien Déglise1, Daniel Teta3 and Jean-Marc Corpataux1

1 Department of Thoracic and Vascular Surgery, Lausanne University Hospital, Lausanne, Switzerland 2 Department of Vascular Medicine, Lausanne University Hospital, Lausanne, Switzerland 3 Department of Nephrology, Lausanne University Hospital, Lausanne, Switzerland

Correspondence and offprint requests to: François Saucy; Email: Francois.saucy{at}chuv.ch



  Abstract

Background. For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis.

Methods. We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded.

Results. Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%.

Conclusions. Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.

Keywords: autogenous fistula; haemodialysis; maturation; thrombosis; vascular access flow

Received for publication: 23. 1.09
Revision received 17. 9.09. Accepted in revised form: 6.10.09


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.