Skip Navigation



NDT Advance Access published online on October 6, 2009

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfp517
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Passauer, J.
Right arrow Articles by Pucalka, K.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Passauer, J.
Right arrow Articles by Pucalka, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press [on behalf of ERA-EDTA]. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study

Jens Passauer1, Helga Petrov2, Andreas Schleser3, Joachim Leicht4 and Klaus Pucalka5

1 Department of Nephrology, University Hospital Carl Gustav Carus, Dresden 2 Department of Nephrology, Evangelisches Krankenhaus Königin Elisabeth Herzberge, Berlin 3 Department of Cardiology, Katharinen-Hospital, Unna 4 Dialysezentrum Schwandorf, Schwandorf 5 Dialysezentrum Thornerstr., Berlin, Germany

Correspondence and offprint requests to: Jens Passauer; E-mail: passauer{at}rcs.urz.tu-dresden.de



  Abstract

Background. Dry weight assessment (DWA) is essential to efficient therapy of haemodialysis (HD) patients. However, so far objective methods for DWA have not been applicable to daily routine. Thus, exact fluid management in HD remains difficult and is often based on clinical criteria. The aims of this study were (1) to objectively define pre- and post-dialytic ranges of extracellular volume in a large cohort of HD patients (in whom DWA had been defined according to clinical criteria), (2) to compare the hydration status between diabetic and non-diabetic patients, and (3) to assess a patient subgroup that might benefit from correction of target weight.

Methods. We measured fluid overload (FO) prior to a mid-week HD session in 370 randomly selected HD patients (50% with diabetes) from five dialysis centres. A new bioimpedance spectroscopy (BIS) device that implies a validated body composition model was applied. This tool allows correct quantification of extracellular FO or – deficiency in comparison to a healthy reference population (normal range 1.1 to 1.1 L according to the 10th and 90th percentile of measurements). In addition, weight and blood pressure were recorded before and after treatment.

Results. Pre-dialytic FO ranged from –0.5 to 4 L and post-dialytic FO from –2.5 to 2 L (10th and 90th percentile of measurements), indicating that on average the hydration status of healthy subjects is considered as the optimal target weight in HD patients. Comparison of FO between diabetic and non-diabetic patients revealed no difference. Based on the consideration that an FO < –1.1 L before and >1.1 L after HD indicates inadequate DWA, we identified 98 (26%) patients who might benefit from correction of target body weight.

Conclusion. BIS is an interesting, objective method to support clinical DWA. Further studies should be performed to investigate beneficial clinical effects of this approach.

Keywords: bioimpedance spectroscopy; extracellular volume; haemodialysis

Received for publication: 14. 8.08
Accepted in revised form: 4. 9.09


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.