Skip Navigation



NDT Advance Access published online on September 17, 2008

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfn518
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
24/2/421    most recent
gfn518v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Rimmelé, T.
Right arrow Articles by Allaouchiche, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rimmelé, T.
Right arrow Articles by Allaouchiche, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2008]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



High-volume haemofiltration with a new haemofiltration membrane having enhanced adsorption properties in septic pigs

Thomas Rimmelé1,2,3, Abdulnasser Assadi2, Mathilde Cattenoz1, Olivier Desebbe2,3, Corine Lambert4, Emmanuel Boselli1,3, Joëlle Goudable3,5, Jérôme Étienne3,6, Dominique Chassard1,3, Giampiero Bricca2,3 and Bernard Allaouchiche1,2,3

1 Department of Anesthesiology and Intensive Care, Pavilion P, Édouard Herriot Hospital 2 INSERM ERI 22, Agressions vasculaires-Réponses tissulaires 3 University of Lyon 1 4 Gambro-Hospal Industries 5 Laboratory of Biochemistry 6 Laboratory of Microbiology, Édouard Herriot Hospital, Lyon, France

Correspondence and offprint requests to: Thomas Rimmelé, Département d’Anesthésie-Réanimation, Pavillon P Réanimation, Hôpital Édouard Herriot, place d’Arsonval, 69003 Lyon, France. Tel: +33-472-110-217; Fax: +33-472-110-275; E-mail: thmrimmele{at}aol.com



  Abstract

Background. High-volume haemofiltration (HVHF) has been suggested as an adjuvant treatment of septic shock due to its capacities to remove from blood both pro- and anti-inflammatory mediators involved in the sepsis syndrome. Adsorption properties of some haemofiltration membranes are also interesting with this indication because inflammatory mediators are caught in the membrane itself. The aim of this study was to determine the haemodynamic and immunological effects of a new haemofiltration membrane, which has enhanced adsorption properties due to a special surface treatment, allowing the adsorption of endotoxins.

Methods. We compared this membrane to a standard haemofiltration membrane both in vitro and in 20 sepsis-induced pigs, randomized in two groups. One group was haemofiltered with the treated membrane and the other with the standard haemofiltration membrane during 6-h HVHF sessions.

Results. At the end of the experiment, mean ± SD crystalloids requirements (5937 ± 1588 versus 7587 ± 1456 ml, P = 0.026), colloids requirements (1437 ± 320 versus 1912 ± 538 ml, P = 0.027), lactic acidosis (pH = 7.20 ± 0.11 versus 7.10 ± 0.07, P = 0.026) and pulmonary arterial hypertension (MPAP = 24 ± 7 versus 34 ± 8 mmHg, P = 0.008) were less pronounced when HVHF was performed with the treated membrane. In addition, mean ± SD endotoxins levels were lower in the treated membrane group after 1 hour of HVHF (1.91 ± 1.19 versus 11.07 ± 10.64 EU/ml, P = 0.035). Cytokines levels were not different between groups except for IL-1β, which was slightly lower in the treated membrane group.

Conclusions. The use of a membrane with enhanced adsorption properties during a 6-h HVHF session in septic pigs improves haemodynamics compared to a standard haemofiltration membrane. These results are probably due to an efficient endotoxins and cytokines adsorption. A human study using this membrane is now necessary to confirm these results.

Keywords: adsorption; cytokine; endotoxin; high-volume haemofiltration; septic shock

Received for publication: 25. 4.08
Accepted in revised form: 22. 8.08


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.