Skip Navigation



NDT Advance Access published online on August 19, 2008

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfn437
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
24/1/104    most recent
gfn437v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Bird, N. J.
Right arrow Articles by Peters, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bird, N. J.
Right arrow Articles by Peters, A. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2008]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Effect of extracellular fluid volume on single-sample measurement of glomerular filtration rate

Nicholas J. Bird1, Christina Peters1, Alastair Robert Michell2 and Adrien Michael Peters1

1 Department of Nuclear Medicine, Addenbrooke's Hospital, Cambridge 2 Department of Biochemical Pharmacology, St Bartholomew's Medical School, London, UK

Correspondence and offprint requests to: Adrien Michael Peters, Audrey Emerton Building, Royal Sussex County Hospital, Eastern Road, Brighton BN2 5BE, UK. Tel: +44-1273-523360; Fax: +44-1273-523366; E-mail: a.m.peters{at}bsms.ac.uk



  Abstract

Objective. The objective of our study was to evaluate the effect of extracellular fluid volume (ECV) on the accuracy of measurement of glomerular filtration rate from a single sample (GFR1).

Methods. Multi-sample GFR (GFR6) and ECV (per 1.73 m2) were measured with both Cr-51-EDTA and iohexol, injected into opposite arms (110 studies in 80 subjects). Six plasma samples were obtained bilaterally 20– 240 min post-injection to measure GFR6/1.73 m2. GFR1/1.73 m2 was calculated from 2-, 3- and 4-h samples using Jacobsson's formula for iohexol and the Christensen and Groth formula for Cr-51-EDTA. The quotient, GFR1/GFR6, was taken to indicate the accuracy of GFR1.

Results. When GFR6 was <60 ml/min/1.73 m2, GFR1/ GFR6 correlated positively with ECV at all single-sample times. When GFR6 was 60–90 ml/min/1.73 m2 or >90 ml/min/1.73 m2, GFR1/GFR6 correlated positively with ECV at 2 h, but negatively at 4 h, indicating that at some time between 2 and 4 h, GFR1/GFR6 was transiently independent of ECV. A plot of the regression gradient of GFR1/GFR6 on ECV against sample time indicated that the time of transient independence, at which time GFR1 depends exclusively on GFR6, was 3.2–3.9 h (depending on indicator combination used) when GFR6 was 60–90 ml/min/1.73 m2 and 2.4–2.9 h when GFR was >90 ml/min/1.73 m2. Transient independence when GFR6 was <60 ml/min/1.73 m2 was not reached by 4 h and estimated to be 5–7 h.

Conclusion. The accuracy of GFR1 depends on ECV, overestimation or underestimation respectively depending on sample time and GFR. The time at which GFR1 is independent of ECV increases with decreasing GFR. If sampling time is too early, GFR1 overestimates GFR, but the reverse occurs when sampling is too late, even if GFR is abnormally low.

Keywords: Cr-51-EDTA; glomerular filtration rate; iohexol; single sample

Received for publication: 25. 4.08
Accepted in revised form: 8. 7.08


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.