Skip Navigation



NDT Advance Access published online on August 5, 2008

Nephrology Dialysis Transplantation, doi:10.1093/ndt/gfn434
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
24/1/252    most recent
gfn434v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Dechmann-Sültemeyer, T.
Right arrow Articles by Voiculescu, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dechmann-Sültemeyer, T.
Right arrow Articles by Voiculescu, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2008]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org



Tandem plasmapheresis and haemodialysis as a safe procedure in 82 patients with immune-mediated disease

Thomas Dechmann-Sültemeyer, Renata Linkeschova, Karl Lenzen, Zdravko Kuril, Bernd Grabensee and Adina Voiculescu

Department of Nephrology, H.-Heine University, Düsseldorf, Germany

Correspondence and offprint requests to: Adina Voiculescu, Department of Nephrology, Universityclinic, Moorenstr. 5, Dusseldorf 40225, Germany. Tel: +49-2118117726; Fax: +49-2118117722; E-mail: voicules{at}uni-duesseldorf.de.



  Abstract

Background. A number of medical, mostly immune-mediated conditions call for a combination therapy consisting of plasmapheresis and haemodialysis. While the two treatments are most commonly applied separately, we describe here the technical details of providing a combined ‘tandem’ treatment.

Method. The components of a dialyzer (polysulfon membrane) and plasma filter are serially connected by a continuous arteriovenous haemofiltration (CAVH) system. In an extracorporeal circulation, using a blood pump the patient's blood is led first to the plasma filter and then into the dialyzer. The substituate connection is located behind the plasma filter and before the dialyzer. At the beginning it is obligatory to carry out an inspection of tubing system leakages. Afterwards, the system is flushed with a heparinized (5000 IE) sodium chloride solution that is removed thereafter.

During the treatment, a blood flow of 150–200 ml/min is possible. In each case, the plasmafiltration and the ultrafiltration should not exceed 25% of the blood flow. The whole time, an intermittent check of blood pressure and heart rate is necessary. The total procedure does not take longer than a routine haemodialysis (3–4 h).

Results. In 82 patients we performed 483 tandem treatments during the last 16 years. None of the patients had volume disturbances caused by plasma shifts and derangements of electrolytes and acid–base balance were immediately equalized. There were no episodes of hypotension or bleeding. Back-filtration did not occur.

Conclusion. Providing both haemodialysis and plasmapheresis at the same time reduces treatment time and thus, overall cost of the treatment. This retrospective analysis shows the tandem treatment to be safe and effective.

Keywords: combined extracorporeal treatments; haemodialysis; plasmapheresis; thrombotic microangiopathy; vasculitis

Received for publication: 21.12.07
Accepted in revised form: 7. 7.08


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.