Nephrol Dial Transplant (2004) 19: 1571-1575
Nephrol Dial Transplant Vol. 19 No. 6 © ERA-EDTA 2004; all rights reserved
Original Article
On the relative safety of parenteral iron formulations
1Division of Nephrology, Department of Medicine, University of California San Francisco, San Francisco, CA, USA, 2Oxford Kidney Unit, Churchill Hospital, Oxford, UK, 3Nebo a/s, Holbaek, Denmark and 4Department of Renal Medicine, Skaraborgs Hospital, Skövde, Sweden
Correspondence and offprint requests to: Glenn M. Chertow, MD, MPH, Department of Medicine Research, University of California San Francisco, UCSF Laurel Heights Suite 430, 3333 California Street, San Francisco, CA 94118-1211, USA. Email: chertowg{at}medicine.ucsf.edu
Background. Intravenous iron is usually required to optimize the correction of anaemia in persons with advanced chronic kidney disease and end-stage renal disease. Randomized clinical trials may have insufficient power to detect differences in the safety profiles of specific formulations.
Methods. We obtained data from the US Food and Drug Administration on reported adverse drug events (ADEs) related to the provision of three formulations of intravenous iron during 19982000. We estimated the relative risks [odds ratios (OR)] of ADEs associated with the use of higher molecular weight iron dextran and sodium ferric gluconate complex compared with lower molecular weight iron dextran using 2 x 2 tables.
Results. The total number of reported parenteral iron-related ADEs was 1981 among
21 060 000 doses administered, yielding a rate of 9.4 x 105, or
94 per million. Total major ADEs were significantly increased among recipients of higher molecular weight iron dextran (OR 5.5, 95% CI 4.96.0) and sodium ferric gluconate complex (OR 6.2, 95% CI 5.47.2) compared with recipients of lower molecular weight iron dextran. We observed significantly higher rates of life-threatening ADEs, including death, anaphylactoid reaction, cardiac arrest and respiratory depression among users of higher molecular weight compared with lower molecular weight iron dextran. There was insufficient power to detect differences in life-threatening ADEs when comparing lower molecular weight iron dextran with sodium ferric gluconate complex.
Conclusions. Parenteral iron-related ADEs are rare. Using observational data, overall and most specific ADE rates were significantly higher among recipients of higher molecular weight iron dextran and sodium ferric gluconate complex than among recipients of lower molecular weight iron dextran. These data may help to guide clinical practice, as head-to-head clinical trials comparing different formulations of intravenous iron have not been conducted.
Keywords: adverse drug events; iron dextran; parenteral iron; sodium ferric gluconate complex
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
S. B. Silverstein, J. A. Gilreath, and G. M. Rodgers Intravenous Iron Therapy: A Summary of Treatment Options and Review of Guidelines Journal of Pharmacy Practice, December 1, 2008; 21(6): 431 - 443. [Abstract] [PDF] |
||||
![]() |
A. Hayat Safety Issues With Intravenous Iron Products in the Management of Anemia in Chronic Kidney Disease Clin. Med. Res., December 1, 2008; 6(3-4): 93 - 102. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Vaage-Nilsen Acute, severe and anaphylactoid reactions are very rare with low-molecular-weight iron dextran, CosmoFer(R) Nephrol. Dial. Transplant., October 1, 2008; 23(10): 3372 - 3372. [Full Text] [PDF] |
||||
![]() |
S. S Shord, J.M. Hamilton Jr, and S. Cuellar Parenteral iron with erythropoiesis-stimulating agents for chemotherapy-induced anemia Journal of Oncology Pharmacy Practice, March 1, 2008; 14(1): 5 - 22. [Abstract] [PDF] |
||||
|
|
D. W. Johnson INTRAVENOUS VERSUS ORAL IRON SUPPLEMENTATION IN PERITONEAL DIALYSIS PATIENTS Perit. Dial. Int., June 1, 2007; 27(Supplement_2): S255 - S260. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. H. Horl Clinical Aspects of Iron Use in the Anemia of Kidney Disease J. Am. Soc. Nephrol., February 1, 2007; 18(2): 382 - 393. [Full Text] [PDF] |
||||
![]() |
G. M. Chertow, P. D. Mason, O. Vaage-Nilsen, and J. Ahlmen Update on adverse drug events associated with parenteral iron Nephrol. Dial. Transplant., February 1, 2006; 21(2): 378 - 382. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. E Saadeh and G. Srkalovic Acute Hypersensitivity Reaction to Ferric Gluconate in a Premedicated Patient Ann. Pharmacother., December 1, 2005; 39(12): 2124 - 2127. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Michael The safety of sodium ferric gluconate complex in haemodialysis patients has been extensively evaluated Nephrol. Dial. Transplant., August 1, 2005; 20(8): 1770 - 1770. [Full Text] [PDF] |
||||
![]() |
I. C Macdougall, K.-U. Eckardt, W. Horl, and On behalf of the Working Group for the revised EPB Reply Nephrol. Dial. Transplant., July 1, 2005; 20(7): 1513 - 1514. [Full Text] [PDF] |
||||
![]() |
O. Vaage-Nilsen Revised European Best Practice Guidelines for the management of anaemia in patients with chronic renal failure, part III.2: treatment of anaemia with iron Nephrol. Dial. Transplant., July 1, 2005; 20(7): 1512 - 1513. [Full Text] [PDF] |
||||
![]() |
B. A. J. Walters and D. B. Van Wyck Benchmarking iron dextran sensitivity: reactions requiring resuscitative medication in incident and prevalent patients Nephrol. Dial. Transplant., July 1, 2005; 20(7): 1438 - 1442. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. R. Bailie, J. A. Clark, C. E. Lane, and P. L. Lane Hypersensitivity reactions and deaths associated with intravenous iron preparations Nephrol. Dial. Transplant., July 1, 2005; 20(7): 1443 - 1449. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Bhowmik and S. C. Tiwari Do we need to change our administration practice with regard to sodium ferric gluconate complex in glucose? Nephrol. Dial. Transplant., June 1, 2005; 20(6): 1279 - 1279. [Full Text] [PDF] |
||||