Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Banerjee, A.
Right arrow Articles by Farrington, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Banerjee, A.
Right arrow Articles by Farrington, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2004) 19: 1528-1532
Nephrol Dial Transplant Vol. 19 No. 6 © ERA-EDTA 2004; all rights reserved


Original Article

The haemodynamic response to submaximal exercise during isovolaemic haemodialysis

Anindya Banerjee, Chiew H. Kong and Ken Farrington

Correspondence and offprint requests to: Dr K. Farrington, Renal Unit, Lister Hospital, Stevenage, Herts SG1 4AB, UK. Email: ken.farrington{at}nhs.net

Introduction. Exercise during haemodialysis has potential benefits but may compromise cardiovascular stability. We studied its acute effects on relative blood volume (RBV) and other haemodynamic parameters.

Methods. Two groups of 10 patients were exercised submaximally using a stationary cycle during isovolaemic dialysis whilst RBV was monitored continuously. In study 1, patients exercised for two 10 min periods separated by 10 min rest. Cardiac output (CO), peripheral vascular resistance (PVR), central blood volume (CBV) and stroke volume were measured using ultrasound dilution immediately before and after each exercise session. In study 2, haemoglobin, serum total protein and albumin levels were measured before and immediately after the exercise session and at the nadir of the RBV trace.

Results. RBV fell immediately on exercise initiation, the maximum reduction being 2.0±1.1% (after 5.9±1.4 min of exercise 1: P<0.001) and 2.0±1.2% (after 4.7±2.3 min of exercise 2: P<0.001). CO increased significantly after both periods of exercise (4.5±0.96 and 5.1±1.1 to 7.2±2.1 and 7.9±2.4 l/min, P<0.001 in both). Stroke volume increased significantly and PVR fell significantly during exercise. CBV increased in absolute terms but fell as a proportion of CO. Mean haemoglobin level at the RBV nadir was significantly higher than baseline (12.3±1.8 vs 11.8±1.7 g/dl: P<0.05: mean change 4.4±2.3%), as was mean total protein concentration (66.0±6.9 vs 62.0±8.1 g/l: P = 0.001: mean change 6.8±5.9%) and mean serum albumin concentration (36.0±3.9 vs 34.1±3.9 g/l: P<0.001: mean change 5.8±3.5%).

Conclusion The haemodynamic response to exercise during haemodialysis is comparable with that in normal individuals. The rapid reduction in RBV on exercise occurs in spite of a significant increase in CO, mainly as a consequence of fluid shifts from the microvasculature to the interstitium.

Keywords: cardiac output; exercise; haemodialysis; haemoglobin; relative blood volume; serum albumin


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
J. J. Dasselaar, R. M. Huisman, P. E. de Jong, and C. F. M. Franssen
Measurement of relative blood volume changes during haemodialysis: merits and limitations
Nephrol. Dial. Transplant., October 1, 2005; 20(10): 2043 - 2049.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. Dasselaar, R. Huisman, and C. Franssen
The haemodynamic response to submaximal exercise during isovolaemic haemodialysis
Nephrol. Dial. Transplant., December 1, 2004; 19(12): 3204 - 3204.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.