Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Hudson, J. Q.
Right arrow Articles by Feldman, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hudson, J. Q.
Right arrow Articles by Feldman, G. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2004) 19: 400-405
© ERA–EDTA 2004; all rights reserved


Original Article

Evaluation of an in vitro dialysis system to predict drug removal

Joanna Q. Hudson1, Thomas J. Comstock2 and George M. Feldman3,4

1Departments of Pharmacy and Medicine (Nephrology), The University of Tennessee, Memphis, TN, 2Department of Pharmacy and 3Department of Internal Medicine-Nephrology, Virginia Commonwealth University, Richmond, VA and 4McGuire VA Medical Center, Richmond, VA, USA

Correspondence and offprint requests to: Joanna Q. Hudson, The University of Tennessee, Department of Pharmacy, 26 South Dunlap Street, Memphis, TN 38163, USA. Email: jhudson{at}utmem.edu

Background. Variation in the extent of drug removal under different dialysis conditions presents a challenge for prediction of drug elimination and dosage regimen adjustment during haemodialysis (HD). Dependence on clinical pharmacokinetic studies in HD patients for dosing guidelines is problematic given the increasing number of dialysers with variable rates of drug removal. Thus, the purpose of this study was to characterize drug removal using an in vitro system and to evaluate its reliability to predict in vivo elimination by HD using vancomycin (VANC) as a model drug.

Methods. In vitro dialysis was performed for 2 h (volume 4.0 l normal saline, initial VANC concentration 30 mg/l, flow rate 300 ml/min, dialysate flow 800 ml/min) using four different dialysers: polymethylmethacrylate (BK-2.1 U), polysulfone (F-80), AN69 (Filtral-20) and hemophan (COBE 700HE). The in vitro dialysis clearance for VANC (CLD) for the polysulfone dialyser was compared with values determined in eight HD patients. In vitro VANC CLD for all dialysers was compared with the clearance and KoA for B12 reported for each dialyser.

Results. In vitro VANC CLD values were 93±11 ml/min for the polymethylmethacrylate BK-2.1, 136±7 ml/min for the AN69, 65±9 ml/min for the hemophan COBE 700HE and 143±10 ml/min for the polysulfone F80. The CLD for the polysulfone F80 was not statistically different from the in vivo CLD of 135±18 ml/min (P = 0.48). In vitro VANC CLD correlated with the B12 CLD (r2 = 0.77) and the B12 KoA (r2 = 0.63) reported for each dialyser.

Conclusion. VANC CLD in HD patients for the polysulfone dialyser was correctly predicted using the in vitro dialysis system. Use of this system may be superior to estimations of drug CLD based on dialyser information provided by the manufacturer for compounds of similar molecular weight.

Keywords: dialysis; drug removal; haemodialysis; pharmacokinetics; vancomycin


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Am J Health Syst PharmHome page
B. S. Crawford, R. F. Largen, T. Walton, and J. J. Doran
Once-weekly vancomycin for patients receiving high-flux hemodialysis
Am. J. Health Syst. Pharm., July 1, 2008; 65(13): 1248 - 1253.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
T. Teraoka, T. Sugai, S. Nakamura, H. Hirasawa, S. Oda, H. Shiga, M. Suga, S. Yamane, H. Ishii, S.-i. Yamagata, et al.
Prediction of iopromide reduction rates during haemodialysis using an in vitro dialysis system
Nephrol. Dial. Transplant., April 1, 2005; 20(4): 754 - 759.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.