Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (7)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Movilli, E.
Right arrow Articles by Maiorca, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Movilli, E.
Right arrow Articles by Maiorca, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2004) 19: 185-189
© ERA–EDTA 2003; all rights reserved


Original Article

Inter-dialytic variations in blood volume and total body water in uraemic patients treated by dialysis

Ezio Movilli, Giovanni C. Cancarini, Silvia Cassamali, Corrado Camerini, Giulio Brunori, Camilla Maffei and Rosario Maiorca

Division of Nephrology, School of Medicine, Spedali Civili and University of Brescia, Brescia, Italy

Correspondence and offprint requests to: Ezio Movilli, MD, Division of Nephrology, Spedali Civili, P. le Ospedale Civile 1, 25123 Brescia, Italy. Email: eziomov{at}libero.it

Background. An optimal balance of sodium and water is one of the most important goals of haemodialysis (HD) therapy. However, while inter-dialytic variations in blood volume (BV) have been well described, very little is known about the dynamics of fluid accumulation and distribution in body compartments during the inter-dialysis period.

Methods. We studied inter-dialysis variations in BV, measured as percent variation of plasma haemoglobin (Hb) concentrations (%{triangleup}BV) and percent variation of total body water (%{triangleup}TBW), in 24 uraemic patients treated by standard bicarbonate dialysis. These parameters were determined at the end of the last weekly dialysis (T0), after 24 h (T1), 48 h (T2), and at the beginning of the following dialysis session (T3). At each time point we measured Hb, haematocrit (Hct), serum albumin (sAlb), plasma sodium (Na), plasma potassium (K), blood urea nitrogen (BUN), plasma osmolality (Osm), body weight (BW), systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR). All patients were clinically stable and had no evidence of acute blood loss in the 3 weeks before the study.

Results. During the inter-dialysis period, there were increases in BUN, K and Osm, but Na did not change. SBP and DBP also did not change. HR tended to decrease, and showed a significant reduction between T0 and T3. TBW increased in a linear fashion whereas BV increased exponentially, showing a slow rise during the first 24 h followed by a greater increase in the following time intervals. This was confirmed by concomitant but opposite percent variations in Hct and sAlb concentrations.

Conclusions. Despite the limitations of the current methodology, our data show that the increase in TBW is redistributed during the long inter-dialysis period and this may prevent the effects of a too premature expansion of the intra-vascular compartment. This is especially evident during the first 24 h after HD, during which %{triangleup}BV is lowest, indicating a preferential distribution of the fluid load towards the extra-vascular space. During the following time intervals, the extra-vascular compartment refills in conjunction with an exponential expansion of BV that reaches its maximum in the last 24 h before HD.

Keywords: blood volume; body weight gain; haemodialysis; inter-dialysis interval


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
E. Movilli, P. Gaggia, R. Zubani, C. Camerini, V. Vizzardi, G. Parrinello, S. Savoldi, M. S. Fischer, F. Londrino, and G. Cancarini
Association between high ultrafiltration rates and mortality in uraemic patients on regular haemodialysis. A 5-year prospective observational multicentre study
Nephrol. Dial. Transplant., December 1, 2007; 22(12): 3547 - 3552.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. J. Dasselaar, R. M. Huisman, P. E. de Jong, and C. F. M. Franssen
Measurement of relative blood volume changes during haemodialysis: merits and limitations
Nephrol. Dial. Transplant., October 1, 2005; 20(10): 2043 - 2049.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.