Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (21)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Canaud, B.
Right arrow Articles by Martin, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Canaud, B.
Right arrow Articles by Martin, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2002) 17: 1286-1292
© 2002 European Renal Association-European Dialysis and Transplant Association

Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses

Bernard Canaud, Hélène Leray-Moragues, Nadia Kerkeni, Jean-Yves Bosc and Katja Martin

Department of Nephrology and Dialysis Research and Training Institute, Lapeyronie University Hospital, CHRU Montpellier, Montpellier, France

Background. Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA).

Methods. To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly.

Results. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316±3.5 ml/min and 340±3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348±2.2 ml/min. Recirculation rates evaluated with the ‘slow blood flow’ method were 8.6±0.6 and 12.1±0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37±0.02 and 1.45±0.02 with DualKT and AVA access respectively. The loss of dialysis efficacy using catheters was estimated at 6%. However, in all cases Kt/Vdp values remained above the recommended values (Kt/Vdp >=1.2). Protein nutritional state, as well as conventional clinical and biochemical markers of dialysis adequacy, remained in the optimal range.

Conclusion. Permanent venous catheters provide adequate haemodialysis on a long-term basis. Flow performances and dialysis doses are slightly reduced (5–6%) when compared with AVA. Regular assessment of dialysis performance is strongly recommended to assure dialysis adequacy. Lengthening dialysis time may represent a simple and efficient tool to compensate for reduced flow performances with catheter use.

Keywords: access adequacy; flow performances; haemodialysis adequacy; permanent catheter; recirculation; vascular access

Correspondence and offprint requests to: Professor Bernard Canaud, MD, Nephrology, Lapeyronie University Hospital, CHRU Montpellier, 371 Avenue du Doyen Gaston Giraud, F-34295 Montpellier, France. Email: b\|[hyphen]\|canaud{at}chu\|[hyphen]\|montpellier.fr


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
J. Ethier, D. C. Mendelssohn, S. J. Elder, T. Hasegawa, T. Akizawa, T. Akiba, B. J. Canaud, and R. L. Pisoni
Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study
Nephrol. Dial. Transplant., October 1, 2008; 23(10): 3219 - 3226.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. C. Fry, J. Stratton, K. Farrington, K. Mahna, S. Selvakumar, H. Thompson, and P. Warwicker
Factors affecting long-term survival of tunnelled haemodialysis catheters a prospective audit of 812 tunnelled catheters
Nephrol. Dial. Transplant., January 1, 2008; 23(1): 275 - 281.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
N. D. C. Duncan, S. Singh, T. D. H. Cairns, M. Clark, A. El-Tayar, M. Griffith, N. Hakim, M. Hamady, A. G. McLean, V. Papalois, et al.
Tesio-Caths provide effective and safe long-term vascular access
Nephrol. Dial. Transplant., November 1, 2004; 19(11): 2816 - 2822.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
R. A. Speckman, D. L. Frankenfield, S. H. Roman, P. W. Eggers, M. R. Bedinger, M. V. Rocco, and W. M. McClellan
Diabetes Is the Strongest Risk Factor for Lower-Extremity Amputation in New Hemodialysis Patients
Diabetes Care, September 1, 2004; 27(9): 2198 - 2203.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.