Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (8)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Smits, H. F. M.
Right arrow Articles by Blankestijn, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smits, H. F. M.
Right arrow Articles by Blankestijn, P. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2002) 17: 467-473
© 2002 European Renal Association-European Dialysis and Transplant Association

Percutaneous thrombolysis of thrombosed haemodialysis access grafts: comparison of three mechanical devices

Henk F. M. Smits1, Johannes H. M. Smits2, Aloys F. J. Wüst1, Erik Buskens3 and Peter J. Blankestijn2,

Departments of 1 Radiology, 2 Nephrology and 3 Clinical Epidemiology, University Medical Center, Utrecht, The Netherlands

Background. Percutaneous thrombolysis has become an accepted treatment of thrombosed haemodialysis grafts. Several devices have been developed for mechanical thrombolysis, which macerate the clot using different mechanisms such as aspiration and fragmentation. The aim of our study was to compare the efficacy of three devices for mechanical thrombolysis in removing the thrombus from thrombosed haemodialysis access grafts and to determine the initial technical and clinical success, complication rates of each device, and graft patency after the procedure.

Methods. Thrombolysis (i.e. clot removal followed by percutaneous transluminal angioplasty (PTA)) was performed in 68 thrombosed haemodialysis grafts using the Cragg brush catheter combined with urokinase in 13, the Hydrolyser in 18 and the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) in 37. Clot removal scores (CRS, the ability to thoroughly remove clot from the access), initial technical success, clinical success, patency at 30, 60, and 90 days, and complication rates were evaluated.

Results. CRS for the Cragg brush, Hydrolyser and PTD were good in 92, 44, and 95% of cases, respectively. Initial technical (85, 83, and 95%) and clinical success (62, 67, and 86%), mean patency rates at 30 (73, 60, and 55%), 60 (61, 53, and 49%), and 90 (49, 40, and 43%) days, stenosis after PTA (33, 46, and 21%) and complication rates (8, 6, and 0%) were not different for the three devices. Success rates and graft patency depended on the effect of PTA, irrespective of the device used.

Conclusions. The rotational devices removed clots more effectively than the Hydrolyser, with the PTD having the advantage of not requiring urokinase. However, the result of PTA in the treatment of underlying stenoses was the only predictive value for graft patency.

Keywords: dialysis shunts; interventional procedures; PTFE; thrombolysis; thrombosis; vascular access; veins

Correspondence and offprint requests to: Peter J. Blankestijn, Department of Nephrology, Room F 03.226, University Medical Center, Heidelberglaan 100, NL-3584 CX Utrecht, The Netherlands. Email: P.J.Blankestijn{at}digd.azu.nl


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.