Nephrol Dial Transplant (2001) 16: 98-101
© 2001 European Renal Association-European Dialysis and Transplant Association
Ultrasound guided puncture of the brachial artery for haemodialysis fistula angiography
First Department of Diagnostic Radiology, Chang Gung Medical Center at Linkou, College of Medicine, Chang Gung University, Taiwan
Background. Arterio-venous (av) fistulae of haemodialysis patients frequently require function assessment by angiography. The purpose of the present study was to determine the efficacy and safety of ultrasound-guided transbrachial catheterization when a-v fistulae were evaluated.
Methods. Between July 1996 and December 1997, 208 dialysis patients, whose a-v fistulae (arterial inflow <50 ml/min or venous pressure >150 mm Hg in three consecutive HD sessions) were at the wrist or elbow, underwent transbrachial angiography using an ultrasound-guided 20-gauge IA needle to evaluate fistula function. Procedure-related symptoms or complications were noted in 28 patients and these were analysed.
Results. No apparent cases of vessel spasm or thrombosis were noted. Reported symptoms in 28 patients (13.5%) included local arm pain (3.3%), transient paresthesia (0.9%), mild ecchymosis (10.6%) and haematoma (0.9%). All complications were minor and none required surgical intervention.
Conclusion. Ultrasound-guided puncture of the brachial artery is a safe, reliable and effective procedure in skilled hands and should be the preferred means of catheterization whenever haemodialysis angiography is performed.
Keywords: brachial arteriography; haemodialysis fistula; ultrasound
Correspondence and offprint requests to: Kar-Wai Lui, MD, First Department of Diagnostic Radiology, Chang Gung Medical Center at Linkou, College of Medicine, Chang Gung University, 5 Fu-Hsing Road, Tao-Yuan Hsien, Taiwan.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
L. Turmel-Rodrigues, A. Mouton, B. Birmele, L. Billaux, N. Ammar, O. Grezard, S. Hauss, and J. Pengloan Salvage of immature forearm fistulas for haemodialysis by interventional radiology Nephrol. Dial. Transplant., December 1, 2001; 16(12): 2365 - 2371. [Abstract] [Full Text] [PDF] |
||||