Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (13)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Bastani, B.
Right arrow Articles by Islam, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bastani, B.
Right arrow Articles by Islam, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (2000) 15: 1035-1037
© 2000 European Renal Association-European Dialysis and Transplant Association

Insufficient penetration of systemic vancomycin into the PermCath lumen

Bahar Bastani, John Minton and Shah Islam

Division of Nephrology, Saint Louis University School of Medicine, St Louis, MO, USA

Background. Catheter infection is a major cause of morbidity and catheter loss in chronic haemodialysis patients. There has been a large discrepancy in the catheter salvage rate, after an episode of documented bacteraemia, whether the patients receive systemic antibiotic alone or systemic antibiotics concomitant with ‘antibiotic-lock technique’ (20–30% vs 100%, respectively). To test the hypothesis that vancomycin may not adequately penetrate into the lumen of the catheter, despite therapeutic plasma levels, a series of in-vivo, ex-vivo, and in-vitro experiments were performed.

Methods. We compared serum and intralumenal (0.3–0.5 ml aspirate from venous port of the catheter) vancomycin concentrations in 24 chronic haemodialysis patients, with documented bacteraemia, who had received prior systemic vancomycin therapy with 14 similar patients who had additionally received ‘vancomycin-lock technique’ (100 µg/ml of vancomycin in heparin solution) after each haemodialysis session.

Results. Despite serum vancomycin concentration of ~17 µg/ml in each group, the vancomycin concentration in the venous hub of the catheter was only 0.2±0.6 µg/ml in the former group, in sharp contrast to 125.6±13 µg/ml in the latter group. In the ex-vivo experiment, four uninfected PermCaths which had been removed were immediately fixed and studied with scanning electron microscopy. No cellular or fibrin barrier could be found at the terminal pore of the catheter interfering with the diffusion of vancomycin from plasma into the catheter lumen. In the in-vitro experiments, three PermCaths filled with standard heparin solution were incubated for 48 h in 100 ml of plasma containing 20 µg/ml of vancomycin. Vancomycin concentration was measured in 0.3–0.5 ml solution aspirated from each port of the catheters. Vancomycin concentration was 0.2±0.1 µg/ml in the aspirated samples. Finally, two PermCaths filled with the standard heparin solution were incubated for 48 h in 100 ml of plasma containing 20 µg/ml of vancomycin, after which the catheters were sectioned at 4-cm intervals. Only the distal 4 cm of the catheters had vancomycin concentrations of 2 and 5 µg/ml, the remaining segments had levels <=0.5 µg/ml.

Conclusion. Our results indicate that diffusion of vancomycin from plasma into the haemodialysis catheter is negligible. Thus, haemodialysis patients with central venous catheter who have to be treated for bacteraemia with systemic antibiotic therapy must always receive ‘antibiotic-lock technique’ of the catheter after each haemodialysis session.

Keywords: haemodialysis; vancomycin; sepsis; bacteraemia; PermCath

Correspondence and offprint requests to: Bahar Bastani, MD, Associate Professor of Internal Medicine, Division of Nephrology, Saint Louis University Health Sciences Center, 3635 Vista Avenue, FDT—9N, St Louis, MO 63110, USA.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Med MicrobiolHome page
Y. Qu, T. S. Istivan, A. J. Daley, D. A. Rouch, and M. A. Deighton
Comparison of various antimicrobial agents as catheter lock solutions: preference for ethanol in eradication of coagulase-negative staphylococcal biofilms
J. Med. Microbiol., April 1, 2009; 58(4): 442 - 450.
[Abstract] [Full Text] [PDF]


Home page
J Antimicrob ChemotherHome page
A. Berrington and F. K. Gould
Use of antibiotic locks to treat colonized central venous catheters
J. Antimicrob. Chemother., November 1, 2001; 48(5): 597 - 603.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.