Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (18)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ezzahiri, R.
Right arrow Articles by Tordoir, J. H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ezzahiri, R.
Right arrow Articles by Tordoir, J. H. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (1999) 14: 2110-2115
© 1999 European Renal Association-European Dialysis and Transplant Association


Dialysis and Transplantation News

Haemodialysis vascular access and fistula surveillance methods in The Netherlands

Raaja Ezzahiri1, M. Susan Lemson1, Peter J. E. H. M. Kitslaar1, Karel M. L. Leunissen2 and Jan H. M. Tordoir1

1 Department of Surgery and 2 Department of Nephrology, University Hospital Maastricht, Maastricht, The Netherlands

Correspondence and offprint requests to: Dr J. H. M. Tordoir, Department of Surgery, University Hospital Maastricht, PO Box 5800, 6202 AZ Maastricht, The Netherlands.

Abstract

Introduction. As the mean age of haemodialysis patients is increasing, fewer patients will have suitable blood vessels for the creation of a Brescia–Cimino fistula and an increased use of graft implants is to be expected.

Methods. To assess the change in vascular access and the use of surveillance techniques, all haemodialysis centres in The Netherlands received a questionnaire regarding the types of vascular accesses and surveillance techniques used in their department on 31 December, 1996. The results were related to a comparable study done in 1987, shown between brackets.

Results. The response of the haemodialysis staff was 96%, of the vascular surgeons this was 91%. Sixty-two per cent (70%) of the patients had Brescia–Cimino fistulas, 21% (13%) Polytetrafluoroethylene (PTFE) graft fistulas, 17% (17%) other vascular accesses. Scheduled surveillance for stenosis detection was done by recirculation measurements in 6%, venous pressure measurements in 31%, Duplex scanning in 11% and angiography in 11% of the centres. When access problems occurred, 79% of the physicians performed recirculation measurements, 38% venous pressure measurements, 79% Duplex scanning and 100% angiography. In 46% of the centres PTA was done occasionally, and in 46% routinely for the treatment of stenotic complications in arteriovenous fistulas.

Conclusions. The use of PTFE grafts and other types of vascular accesses has increased at the expense of BC fistulas. Recirculation and venous pressure measurements are primarily done when problems occur and not according to a standard surveillance schedule. For visualization of failing fistulas, 79% of the centres uses Duplex ultrasound analysis and 100% angiography. The popularity of PTA has increased from 46 to 92% of the centres.

Keywords: arteriovenous fistula; Brescia–Cimino fistula; fistula surveillance; haemodialysis; polytetrafluoroethylene; vascular access

Notes

Editor's note

Please see also Invited Comment by Konner (pp. 2094–2098) and Dialysis and Transplantation News by Bonucchi et al. (pp. 2116–2118).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J. Am. Soc. Nephrol.Home page
T. Kokubo, N. Ishikawa, H. Uchida, S. E. Chasnoff, X. Xie, S. Mathew, K. A. Hruska, and E. T. Choi
CKD Accelerates Development of Neointimal Hyperplasia in Arteriovenous Fistulas
J. Am. Soc. Nephrol., June 1, 2009; 20(6): 1236 - 1245.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
H. J. T. A. M. Huijbregts, M. L. Bots, F. L. Moll, P. J. Blankestijn, and on behalf of the CIMINO members
Accelerated increase of arteriovenous fistula use in haemodialysis centres: results of the multicentre CIMINO initiative
Nephrol. Dial. Transplant., September 1, 2007; 22(9): 2595 - 2600.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. van Loon, W. van der Mark, N. Beukers, C. de Bruin, P. J. Blankestijn, R. M. Huisman, J. J. Zijlstra, F. M. van der Sande, and J. H. M. Tordoir
Implementation of a vascular access quality programme improves vascular access care
Nephrol. Dial. Transplant., June 1, 2007; 22(6): 1628 - 1632.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. O. Trerotola and L. A. Turmel-Rodrigues
Off the Beaten Path: Transbrachial Approach for Native Fistula Interventions
Radiology, March 1, 2001; 218(3): 617 - 619.
[Full Text]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.