Skip Navigation

This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (22)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Vorbeck-Meister, I.
Right arrow Articles by Horl, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vorbeck-Meister, I.
Right arrow Articles by Horl, W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrology Dialysis Transplantation, Vol 14, Issue 3 666-675, Copyright © 1999 by Oxford University Press


ORIGINAL ARTICLES

Quality of water used for haemodialysis: bacteriological and chemical parameters

I Vorbeck-Meister, R Sommer, F Vorbeck and W Horl
Hygiene Institute, University of Vienna, Kinderspitalgasse 15, A-1095 Vienna, Austria; Department of Radiology 6F and Department of Nephrology and Dialysis, General Hospital, University of Vienna, Vienna, Austria; Corresponding author

Background. The bacterial and chemical contamination of dialysate fluids are important problems in haemodialysis therapy and may be caused by the water used for dialysate preparation. Methods. We performed a survey of the microbiological and chemical quality of the water used in seven dialysis wards. Special attention was paid to the effects of each water treatment step, for example ion exchange, reverse osmosis and UV disinfection, on the number of bacteria (measured as colony forming units, CFU), the amount of endotoxin (endotoxin units, EU) and various chemical parameters, the main focus being on calcium, magnesium, sulphate, aluminium and heavy metals. Results. CFU values exceeding the European Pharmacopeia value, determined at an incubation temperature of 22°C, were found in the samples of raw water (20.0%, n=25), after ion exchange (66.7%, n=12), after reverse osmosis (33.3%, n=18) and also in samples of the dialysis water taken at the inlets (12.5%, n=40) and outlets (50.0%, n=18) of the machines. Whereas all raw water samples from the wards showed high mean values for endotoxin (0.56-9.10 EU/ml) and the endotoxin levels were often enhanced after ion exchange (0.13->9.49 EU/ml), treatment by reverse osmosis led to a satisfactory decrease in endotoxin all samples (<0.03 EU/ml). Sufficient reductions in calcium, magnesium and sulphate could only be achieved by the combined application of ion exchange and reverse osmosis. Mercury contamination was observed in the samples after ion exchange at three treatment plants, this was possibly caused by polluted regenerants. Increased amounts of aluminium, copper and zinc were found in water samples from different sites in the treatment systems and were caused by materials in contact with the water. Conclusions. A sufficient chemical water purification treatment system should consist of ion exchange and reverse osmosis. Attention has to be paid to the suitability of materials in contact with the water and of the chemicals used, for example regenerants or corrosion inhibitors. From the microbiological point of view, a safety UV disinfection step in the water treatment system is favourable. To avoid bacterial recontamination periodic cleaning and disinfecting of the water-treatment and distribution systems, as well as the dialysis machine are essential. There is the need for complete guidelines regarding dialysis water that include all relevant chemical and microbiological parameters. Based on this standard, periodic examination of the water after each treatment step has to be performed. Keywords: bacteria; chemical parameters; endotoxin; heavy metals; haemodialysis; water
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
N. Yamaguchi, T. Baba, S. Nakagawa, A. Saito, and M. Nasu
Rapid monitoring of bacteria in dialysis fluids by fluorescent vital staining and microcolony methods
Nephrol. Dial. Transplant., February 1, 2007; 22(2): 612 - 616.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Perez-Garcia and P. Rodriguez-Benitez
Chloramine, a sneaky contaminant of dialysate
Nephrol. Dial. Transplant., November 1, 1999; 14(11): 2579 - 2582.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
D. Richardson, C. Bartlett, E. Goutcher, C. H. Jones, A. M. Davison, and E. J. Will
Erythropoietin resistance due to dialysate chloramine: the two-way traffic of solutes in haemodialysis
Nephrol. Dial. Transplant., November 1, 1999; 14(11): 2625 - 2627.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.