Skip Navigation

This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Fernandez-Martin, J.
Right arrow Articles by Andia, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fernandez-Martin, J.
Right arrow Articles by Andia, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrology Dialysis Transplantation, Vol 13, Issue 90003 78-81, Copyright © 1998 by Oxford University Press


ORIGINAL ARTICLES

Prevention of aluminium exposure through dialysis fluids. Analysis of changes in the last 8 years

J Fernandez-Martin, A Canteros, M Serrano, A Gonzalez-Carcedo, C Diaz-Corte and J Andia
Bone and Mineral Research Unit, Hospital Central de Asturias, Instituto Reina Sofia de Investigacion, Oviedo, Spain; Corresponding author address: Metabolismo Oseo y Mineral, Instituto Reina Sofia de Investigacion, Hospital Central de Asturias, c/Julian Claveria s/n, E-33006 Oviedo, Asturias, Spain

Despite extensive measures to control aluminium exposure, chronic and acute episodes of aluminium intoxication still occur. The objective of this study was to analyse the changes in the aluminium content of dialysis fluid and the effect on serum aluminium in different dialysis centres in Spain in the last 8 years. For this purpose, the aluminium content in dialysis fluid and serum samples (N=5609) from 17 dialysis centres was analysed for >8 years (from the last quarter of 1988 to 1996). In that period of time, the percentage of dialysis fluid samples with acceptable concentrations of aluminium (<2 &mgr;g/l) increased from 0% in 1988 to 80% in 1996. The percentage of dialysis fluid samples with high aluminium levels (>6 &mgr;g/l) ranged between 37.5% in 1988 and 2.3% in 1996. The improvement in the quality of the dialysis fluid resulted in lower values of serum aluminium. The percentage of serum samples with low aluminium (<20 &mgr;g/l) increased from 16.5% in 1988 to 54.2% in 1966. The mean serum aluminium correlated with the mean dialysis fluid aluminium (r=0.55, P<0.001). A higher correlation was found when the aluminium in dialysis fluid ranged between 4 and 10 &mgr;g/l (r=0.802, P<0.001), and no correlation was found when the aluminium in dialysis fluid was <4 &mgr;g/l. Even taking into account that the dialysis fluid is not the only source of aluminium for dialysis patients, our study clearly demonstrated a close relationship with the serum aluminium content. Therefore, we must emphasize the necessity for controlling the aluminium content in dialysis fluid more often than is done at present.Keywords: aluminium exposure; dialysis fluid; haemodialysis; quality of dialysis
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.